MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00784-023-05161-5

Медицинская библиотека · Clinical oral investigations · 2023

Accuracy and patient-centered results of static and dynamic computer-assisted implant surgery in edentulous jaws: a retrospective cohort study.

Fu Shuang, Sun Wei, Zhu Jingxian, Huang Bin, Ji Wei, Shi Bin

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

This study aimed to compare implant positioning accuracy and patient-centered results between static and dynamic computer-assisted implant surgery (s-CAIS and d-CAIS) in edentulous jaws.

MATERIAL AND

METHODS

The current study retrospectively evaluated a total of 110 implants placed in 22 fully edentulous patients via s-CAIS or d-CAIS (n = 11). The accuracy of implant positioning was assessed by measuring the implant's angular deviation and deviation at the platform and apex from the preoperative design postoperatively. Patient-centered results, including preoperative and intraoperative patient-reported experiences and postoperative patient-reported outcomes, were extracted from the medical records. The nested t test and chi-square test were used to compare accuracy and patient-centered results between s-CAIS and d-CAIS postoperatively.

RESULTS

The implants in the s-CAIS group showed significantly smaller angular deviation (2.32 ± 1.23°) than those in the d-CAIS group (3.87 ± 2.75°). In contrast, the platform and apical deviation were significantly larger in s-CAIS (1.56 ± 1.19 mm and 1.70 ± 1.09 mm, respectively) than d-CAIS (1.02 ± 0.45 mm and 1.00 ± 0.51 mm, respectively). Furthermore, the implants in the s-CAIS group deviated significantly (p < 0.001) more toward the coronal direction than those in the d-CAIS group. Notably, all patients in the s-CAIS group reported an obvious foreign body sensation during surgery, representing a significant difference from the d-CAIS group.

CONCLUSIONS

Compared to s-CAIS, d-CAIS is a reliable technique for the placement of multiple implants in fully edentulous patients with less linear deviation and less foreign body sensation.

TRIAL REGISTRATION: The retrospective study was registered on the Chinese Clinical Trial Registry on August 8th, 2022, with registration number No. ChiCTR2200062484.

CLINICAL RELEVANCE: Despite the increasing use of computer- assisted implant surgery in fully edentulous patients, clinical evidence comparing implant positioning accuracy and patient-centered results between static and dynamic CAIS systems is scarce. Our study demonstrated that compared to s-CAIS, d-CAIS is a reliable technique for the placement of multiple implants in fully edentulous patients with less linear deviation.

Для цитирования: Fu Shuang, Sun Wei, Zhu Jingxian, Huang Bin, Ji Wei, Shi Bin. Accuracy and patient-centered results of static and dynamic computer-assisted implant surgery in edentulous jaws: a retrospective cohort study.. Clinical oral investigations. 2023. DOI: 10.1007/s00784-023-05161-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.