MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d4ay02263g

Медицинская библиотека · Analytical methods : advancing methods and applications · 2025

Structural analysis of synthetic opioids using travelling wave ion mobility-mass spectrometry (TWIM-MS).

Reyes Monroy Karen Abigail, Perez Daillin L, Demmelash Rebecca, Ngo Lilly T, Mancilla Rodriguez Ariana M, Castro Haley A, Wiese Noah R, Murillo Wilbert A, Golden Dr Teresa D, Verbeck Dr Guido F

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Traveling wave ion mobility-mass spectrometry (TWIM-MS) has emerged as a powerful tool for the identification of synthetic opioids, such as fentanyl and its analogs. However, due to its novelty, only a few fentanyl analogs have been studied using this technology and alternative drift gases, apart from the commonly employed nitrogen gas. Here we introduce the largest compendium of measured TWCCSN2, TWCCSHe, and TWCCSCO2 values for fentanyl-related compounds. This compendium of mobility-derived CCS molecular descriptors for precursor [M + H]+ ions can be used to assign fentanyl identities. Here, we report collision-cross section (CCS) values for precursor [M + H]+ ions of 110 fentanyl analogs, 7 fentanyl precursors, and 31 non-fentanyl related synthetic opioids measured using three mobility gases; nitrogen, helium, and carbon dioxide. Measured TWCCSN2 values show high agreement with previously published collision cross-section values obtained via drift-tube ion mobility (DTIM) MS, with differences ranging from -0.1 to 1.3%. Additionally, computationally derived CCS values for each fentanyl analyte were calculated using MobCross, with a difference range of ±3-15% between theoretical and experimental values.

Для цитирования: Reyes Monroy Karen Abigail, Perez Daillin L, Demmelash Rebecca, Ngo Lilly T, Mancilla Rodriguez Ariana M, Castro Haley A, Wiese Noah R, Murillo Wilbert A, Golden Dr Teresa D, Verbeck Dr Guido F. Structural analysis of synthetic opioids using travelling wave ion mobility-mass spectrometry (TWIM-MS).. Analytical methods : advancing methods and applications. 2025. DOI: 10.1039/d4ay02263g.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.