m+Medelevator.RU
← Поиск публикаций
Heart rhythm · 2024

A novel endocardial activation-derived predictor for focal paraseptal atrial tachycardias: Evidence from a multicenter cohort study.

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kong Ling-Cong, Shuang Tian, Tan Hong-Wei, Sun Yu-Min, Han Bing, Wang Xin-Hua

Аннотация

BACKGROUND: The electrocardiogram-based algorithm for predicting paraseptal atrial tachycardia (PSAT) is limited by the significant overlaps in P-wave morphology originating from various paraseptal sites.

OBJECTIVES: The goals of this study were to investigate the endocardial activation characteristics of PSAT and to seek an endocardial activation-derived predictor for the ablation site.

METHODS: Forty-four patients [11 men (25%); mean age 62.6 ± 14.7 years] with PSAT ablation in 4 tertiary medical centers were assigned to 3 groups according to the ablation site: right atrial (RA) para-Hisian region (group 1, n = 10), noncoronary cusp (NCC) (group 2, n = 13), and left atrial (LA) paraseptal area (group 3, n = 21). Multiple-chamber activation mapping was performed guided by a 3-dimensional navigation system. The discrepancies in the earliest activation time between 2 of 3 chambers (ΔRA-LA, ΔRA-NCC, and ΔLA-NCC) were calculated in each group and used for pairwise comparisons.

RESULTS: There was a significant difference in ΔRA-LA, ΔRA-NCC, and ΔLA-NCC among the 3 groups. ΔRA-LA was the only parameter that could consistently predict the ablation site of PSAT with good accuracy (area under the curve 1.000, sensitivity 100% and specificity 100%, and cutoff value 7 ms for predicting right para-Hisian or NCC ablation; area under the curve 0.974, sensitivity 92.3% and specificity 95.2%, and cutoff value -4 ms for predicting NCC or left paraseptal ablation). Based on 2 cutoff values, a 2-step algorithm was developed to predict the ablation site of PSAT with a positive predictive value of 95.4% and a negative predictive value of 97.0%.

CONCLUSION: ΔRA-LA is a useful endocardial activation-derived parameter for predicting the successful ablation site of PSAT.