Coronary Endothelium-Dependent Vasomotor Function After Drug-Eluting Stent and Bioresorbable Scaffold Implantation.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Gomez-Lara Josep, Oyarzabal Loreto, Ortega-Paz Luis, Brugaletta Salvatore, Romaguera Rafael, Salvatella Neus, Roura Gerard, Rivero Fernando, Fuentes Lara, Alfonso Fernando, Otaegui Imanol, Vandeloo Bert, Vaquerizo Beatriz, Sabate Manel, Comin-Colet Josep, Gomez-Hospital Joan-Antoni
Аннотация
Background Early generation drug-eluting stents (DESs) showed a high grade of coronary endothelial dysfunction that was attributed to lack of stent reendothelialization. Endothelium-dependent vasomotor response of current DESs and bioresorbable scaffolds (BRSs) remains unknown. This study sought to assess the device-related endothelial function of current devices and to correlate neointima healing with endothelial function. Methods and Results A total of 206 patients from 4 randomized trials treated with the durable-polymer everolimus-eluting Xience (n=44), bioresorbable-polymer sirolimus-eluting Orsiro (n=35), polymer-free biolimus-eluting Biofreedom (n=24), bioactive endothelial-progenitor cell-capturing sirolimus-eluting Combo DES (n=25), polymer-based everolimus-eluting Absorb (n=44), and Mg-based sirolimus-eluting Magmaris BRS (n=34) underwent endothelium-dependent vasomotor tests and optical coherence tomography imaging, as per protocol, at follow-up. Crude vasomotor responses of distal segments to low-dose acetylcholine (10-6 mol/L) were different between groups: bioresorbablepolymer DEShad the worst (-8.4%±12.6%) and durable-polymer DES had the most physiologic (-0.4%±11.8%; P=0.014). High-dose acetylcholine (10-4 mol/L) showed similar responses between groups (ranging from -10.8%±11.6% to -18.1%±15.4%; P=0.229). Device healing was different between devices. Uncovered struts ranged from 6.3%±7.1% (bioresorbable-polymer DES) to 2.5%±4.5% (bioactive DES; P=0.056). In multivariate models, endothelium-dependent vasomotor response was associated with age, bioresorbable-polymer DES, and angiographic lumen loss, but not with strut coverage nor plaque type. Endothelial dysfunction (defined as ≥4% vasoconstriction) was observed in 46.6% of patients with low-dose and 68.9% with high-dose acetylcholine, without differences between groups. Conclusions At follow-up, endothelial dysfunction was frequently observed in distal segments treated with current stents without remarkable differences between devices. Although neointima healing was different between devices, poor healing was not associated with endothelial dysfunction.