OBJECTIVES

Limited data are available regarding the occurrence and the extent of cardiac rhythm disturbances in patients with COVID-19 treated with Remdesivir.

METHODS

We present a case series of 52 patients who underwent daily electrocardiogram (ECG) examination after Remdesivir administration.

RESULTS

Compared to baseline, a significant heart rate reduction was observed after initiation of Remdesivir; however, no case of severe bradycardia or arrhythmias leading to significant clinical complications or Remdesivir discontinuation occurred. Heart rate reduction was proportional to baseline heart rate values (r=0.75, p<0.001). By multivariate analysis, a less severe clinical presentation of Covid-19 (beta=0.47, p<0.01) was related to lower heart rate levels observed after Remdesivir administration.

CONCLUSIONS

Despite a significant reduction in heart rate observed after Remdesivir administration, no severe cardiovascular toxicity was observed in Covid-19 patients, even in the case of cardiovascular comorbidities.

Для цитирования: Brunetti Natale Daniele, Poliseno Mariacristina, Bottalico Irene Francesca, Centola Antonio, Montemurro Laura, Sica Salvatore, Santantonio Teresa, Lo Caputo Sergio. Safety and heart rate changes in Covid-19 patients treated with Remdesivir.. International journal of infectious diseases : IJID : official publication of the International Society for Infectious Diseases. 2021. DOI: 10.1016/j.ijid.2021.09.036.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.