MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0078926

Медицинская библиотека · PloS one · 2013

A novel scoring system to measure radiographic abnormalities and related spirometric values in cured pulmonary tuberculosis.

Báez-Saldaña Renata, López-Arteaga Yesenia, Bizarrón-Muro Alma, Ferreira-Guerrero Elizabeth, Ferreyra-Reyes Leticia, Delgado-Sánchez Guadalupe, Cruz-Hervert Luis Pablo, Mongua-Rodríguez Norma, García-García Lourdes

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Despite chemotherapy, patients with cured pulmonary tuberculosis may result in lung functional impairment.

OBJECTIVE

To evaluate a novel scoring system based on the degree of radiographic abnormalities and related spirometric values in patients with cured pulmonary tuberculosis.

METHODS

One hundred and twenty seven patients with cured pulmonary tuberculosis were prospectively enrolled in a referral hospital specializing in respiratory diseases. Spirometry was performed and the extent of radiographic abnormalities was evaluated twice by each of two readers to generate a novel quantitative score. Scoring reproducibility was analyzed by the intra-class correlation coefficient (ICC) and the Bland-Altman method. Multiple linear regression models were performed to assess the association of the extent of radiographic abnormalities with spirometric values.

RESULTS

The intra-observer agreement for scoring of radiographic abnormalities (SRA) showed an ICC of 0.81 (CI:95%, 0.67-0.95) and 0.78 (CI:95%, 0.65-0.92), for reader 1 and 2, respectively. Inter-observer reproducibility for the first measurement was 0.83 (CI:95%, 0.71-0.95), and for the second measurement was 0.74 (CI:95%, 0.58-0.90). The Bland-Altman analysis of the intra-observer agreement showed a mean bias of 0.87% and -0.55% and an inter-observer agreement of -0.35% and -1.78%, indicating a minor average systematic variability. After adjustment for age, gender, height, smoking status, pack-years of smoking, and degree of dyspnea, the scoring degree of radiographic abnormalities was significantly and negatively associated with absolute and percent predicted values of FVC: -0.07 (CI:95%, -0.01 to -0.04); -2.48 (CI:95%, -3.45 to -1.50); and FEV1 -0.07 (CI:95%, -0.10 to -0.05); -2.92 (CI:95%, -3.87 to -1.97) respectively, in the patients studied.

CONCLUSION

The extent of radiographic abnormalities, as evaluated through our novel scoring system, was inversely associated with spirometric values, and exhibited good reliability and reproducibility. As intra-observer and inter-observer agreement of the SRA varied from good to excellent, the use of SRA in this setting appears acceptable.

Для цитирования: Báez-Saldaña Renata, López-Arteaga Yesenia, Bizarrón-Muro Alma, Ferreira-Guerrero Elizabeth, Ferreyra-Reyes Leticia, Delgado-Sánchez Guadalupe, Cruz-Hervert Luis Pablo, Mongua-Rodríguez Norma, García-García Lourdes. A novel scoring system to measure radiographic abnormalities and related spirometric values in cured pulmonary tuberculosis.. PloS one. 2013. DOI: 10.1371/journal.pone.0078926.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.