MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/brs.0000000000000709

Медицинская библиотека · Spine · 2015

Posterior reduction and temporary fixation for odontoid fracture: a salvage maneuver to anterior screw fixation.

Ni Bin, Guo Qunfeng, Lu Xuhua, Xie Ning, Wang Liang, Guo Xiang, Chen Fei

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

DESIGN

A prospective study.

OBJECTIVE

To evaluate the outcomes of posterior reduction and temporary fixation using the C1-C2 screw-rod system for odontoid fracture unsuitable for anterior screw fixation.

SUMMARY OF BACKGROUND DATA: Anterior screw fixation has become the most widely used surgical procedure for the stabilization of odontoid fractures. However, if there is any contraindication for anterior fixation, posterior atlantoaxial fusion is preferred, eliminating the normal rotation of the atlantoaxial complex.

METHODS

A consecutive series of 22 patients with odontoid fracture unsuitable for anterior screw fixation were involved in this study. Posterior reduction and fixation without fusion using the C1-C2 screw-rod system was performed. Once fracture healing was obtained, instrumentation was removed. The visual analogue scale of neck pain, neck stiffness, American Spinal Injury Association impairment scale, patient satisfaction, and neck disability index were recorded. The range of motion of C1-C2 in flexion-extension and rotation was calculated.

RESULTS

The average age at internal fixation surgery was 40.2±11.3 years. The mean duration of follow-up was 41.8±26.8 months. There were no complications associated with instrumentation. All patients returned to their preoperative work. Fracture healing was observed in 21 patients and the instrumentation was removed. After removing the instrumentation, the visual analogue scale was reduced and neck stiffness were relieved (all P<0.01). Patient satisfaction and neck disability index had improved (all P<0.01). The range of motion of C1-C2 returned to 4.75°±1.62° and 25.70°±5.51° in flexion-extension and in rotation, respectively. No osteoarthritis was observed at the C1-C2 lateral mass joints.

CONCLUSION

Posterior reduction and temporary fixation using the C1-C2 screw-rod system was an optimal salvage maneuver to anterior screw fixation for odontoid fracture. It could effectively avoid the motion loss of C1-C2 caused by posterior atlantoaxial fusion.

LEVEL OF EVIDENCE: 3.

Для цитирования: Ni Bin, Guo Qunfeng, Lu Xuhua, Xie Ning, Wang Liang, Guo Xiang, Chen Fei. Posterior reduction and temporary fixation for odontoid fracture: a salvage maneuver to anterior screw fixation.. Spine. 2015. DOI: 10.1097/brs.0000000000000709.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.