DOI 10.1016/j.eururo.2011.10.036
The inside-out transobturator male sling for the surgical treatment of stress urinary incontinence after radical prostatectomy: midterm results of a single-center prospective study.
Аннотация
BACKGROUND
Transobturator slings are currently promoted for the treatment of stress urinary incontinence (SUI) after radical prostatectomy (RP), but data on outcome remain limited.
OBJECTIVE
To assess, at midterm, the efficacy and safety of the inside-out transobturator male sling for treating post-RP SUI and to determine factors associated with failure.
DESIGN, SETTING, AND
PARTICIPANTS
Prospective one-center trial involving 173 consecutive patients without detrusor overactivity, treated between 2006 and 2011 for SUI following RP.
INTERVENTION: Placement of an inside-out transobturator sling.
MEASUREMENTS: Baseline and follow-up evaluations included uroflowmetry and continence and quality-of-life (QoL) questionnaires. Cure was defined as no pad use and improvement as a number of pads per day reduced by ≥50% and two or fewer pads. Complications were recorded, and factors associated with treatment failure were evaluated.
RESULTS AND LIMITATIONS: Preoperatively, 21%, 35%, and 44% of the patients were using two, three to five, and more than five pads per day, respectively. After a median follow-up of 24 mo (range: 12-60 mo), 49% were cured, 35% improved, and 16% not improved. QoL was enhanced (p<0.001), and 72% of patients were moderately to completely satisfied with the procedure. Maximum flow rates were slightly reduced (p=0.004); postvoid residual volumes were similar (p=0.097). Complications were urinary retention after catheter removal (15%), perineal/scrotal hematoma (9%), pain lasting >6 mo (3%), and sling infection (2%); all were managed conservatively. Severe SUI before sling surgery was not associated with a worse outcome, whereas obesity and a history of pelvic irradiation or bladder neck stenosis were independent risk factors of failure, with risk ratios of 7.9 (95% confidence interval [CI], 3.3-18.9), 3.3 (95% CI, 1.4-7.8), and 2.6 (95% CI, 1.1-6.5), respectively.
CONCLUSIONS
The inside-out transobturator male sling is an efficient and safe treatment for post-RP SUI at midterm. Patients with prior pelvic irradiation may not be suitable candidates.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.