m+Medelevator.RU
← Поиск публикаций
Circulation research · 1993

A redox-based O2 sensor in rat pulmonary vasculature.

СтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Archer S L, Huang J, Henry T, Peterson D, Weir E K

Аннотация

The effector mechanism of hypoxic pulmonary vasoconstriction (HPV) involves K+ channel inhibition with subsequent membrane depolarization. It remains uncertain how hypoxia modulates K+ channel activity. The similar effects of hypoxia and mitochondrial electron transport chain (ETC) inhibitors on metabolism and vascular tone suggest a common mechanism of action. ETC inhibitors and hypoxia may alter cell redox status by causing an accumulation of electron donors from the Krebs cycle and by decreasing the production of activated O2 species (AOS) by the ETC. We hypothesized that this shift toward a more reduced redox state elicits vasoconstriction by inhibition of K+ channels. Pulmonary artery pressure and AOS, measured simultaneously using enhanced chemiluminescence, were studied in isolated perfused rat lungs during exposure to hypoxia, proximal ETC inhibitors (rotenone and antimycin A), and a distal ETC inhibitor (cyanide). Patch-clamp measurements of whole-cell K+ currents were made on freshly isolated rat pulmonary vascular smooth muscle cells during exposure to hypoxia and ETC inhibitors. Hypoxia, rotenone, and antimycin A decreased lung chemiluminescence (-62 +/- 12, -46 +/- 7, and -148 +/- 36 counts/0.1 s, respectively) and subsequently increased pulmonary artery pressure (+14 +/- 2, +13 +/- 3, and +21 +/- 3 mm Hg, respectively). These agents reversibly inhibited an outward, ATP-independent, K+ current in pulmonary vascular smooth muscle cells. Antimycin A and rotenone abolished subsequent HPV. In contrast, cyanide increased AOS and did not alter K+ currents or inhibit HPV. The initial effect of rotenone, antimycin A, and hypoxia was a change in redox status (evident as a decrease in production of AOS). This was associated with the reversible inhibition of an ATP-independent K+ channel and vasoconstriction. These findings are consistent with the existence of a redox-based O2 sensor in the pulmonary vasculature.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты