BACKGROUND

Homologous recombination repair (HRR) is the main mechanism of repair of DNA double-strand breaks. Its deficiency (HRD) is a common feature of epithelial ovarian cancers (EOCs). BRCA1/2 mutations and/or other aberrations in genes of HRR are well known causes of HRD and genomic instability. Poly ADP-ribose polymerase inhibitors (PARPi) have revolutionized the management of BRCA mutant EOCs and demonstrated activity in HRD tumor cells. Determining HRD status can provide informations on the magnitude of benefit for PARPi therapy. Myriad MyChoice CDx is a next generation sequencing- based in vitro diagnostic test that assesses the Genomic Instability Score (GIS) which is an algorithmic measurement of loss of heterozygosity, telomeric allelic imbalance, and large-scale state transitions using DNA isolated from formalin-fixed paraffin embedded tumor tissue specimens. However Myriad MyChoice CDx, is a centrally performed and costly assay, with no reimbursement scheduled, at least in Italy.

METHODS

In this report, we described our experience in performing the HRD Focus AmoyDx (Amoy Diagnostics Ltd, Xiamen, Fujian, China) on the same samples of EOCs evaluated with Myriad MyChoiceCDx assay.

RESULTS

The overall percent agreement between AmoyDx and Myriad was 87.8% (65 of 74 tumors tested). All the 36 AmoyDx negative cases were confirmed to be negative by Myriad (negative predictive value, 100%).

CONCLUSIONS

The concordance of the results with the gold standard Myriad MyChoice CDx assay suggest the feasibility and reliability of HRD testing in diagnostic laboratories with high-throughput NGS platforms and qualified personnel.

Для цитирования: Fumagalli Caterina, Betella Ilaria, Ranghiero Alberto, Guerini-Rocco Elena, Bonaldo Giulio, Rappa Alessandra, Vacirca Davide, Colombo Nicoletta, Barberis Massimo. In-house testing for homologous recombination repair deficiency (HRD) testing in ovarian carcinoma: a feasibility study comparing AmoyDx HRD Focus panel with Myriad myChoiceCDx assay.. Pathologica. 2022. DOI: 10.32074/1591-951x-791.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.