Green approach for simultaneous determination of long-acting β-agonists, their organic counterparts and corticosteroids by HPLC coupled with PDA detector.

Gupta Sweta, Desai Sonal

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Accurate, precise and robust HPLC method was developed for the simultaneous estimation of long-acting β2 agonist drugs (formoterol fumarate, salmeterol xinafoate and vilanterol trifenatate) along with two organic counterparts (xinafoic acid and triphenyl acetic acid) and inhaled corticosteroids (fluticasone propionate and fluticasone furoate).

MATERIAL AND

METHODS

The separation was carried out using C18 column (250×4.6mm, 5μ) with eluent comprising of 0.05% orthophosphoric acid: methanol: acetonitrile (40:30:30, v/v/v) at a 1mL/min flow rate.

RESULTS

Linearity was observed in the concentration ranges of 1.5-12μg/mL for formoterol fumarate, 2.82-22.6μg/mL for xinafoic acid, 6.25-50μg/mL for vilanterol, 3.12-25μg/mL for salmeterol, 2.0-15.2μg/mL for triphenyl acetic acid, 62.5-500μg/mL for fluticasone propionate and 25-200μg/mL for fluticasone furoate.

CONCLUSION

The proposed method was accurate, precise and robust and results were within the limit as per the ICH (Q2R1) guidelines. Additionally, the proposed method was found to be green and sustainable when analysed by different green analytical tools namely GAPI, AGREE, AGREEprep and BAGI.

Для цитирования: Gupta Sweta, Desai Sonal. Green approach for simultaneous determination of long-acting β-agonists, their organic counterparts and corticosteroids by HPLC coupled with PDA detector.. Annales pharmaceutiques francaises. 2025. DOI: 10.1016/j.pharma.2025.01.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.