MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/ard.2003.015081

Медицинская библиотека · Annals of the rheumatic diseases · 2004

Standard reference values for musculoskeletal ultrasonography.

Schmidt W A, Schmidt H, Schicke B, Gromnica-Ihle E

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To determine standard reference values for musculoskeletal ultrasonography in healthy adults.

METHODS

Ultrasonography was performed on 204 shoulders, elbows, hands, hips, knees, and feet of 102 healthy volunteers (mean age 38.4 years; range 20-60; 54 women) with a linear probe (10-5 MHz; Esaote Technos MP). Diameters of tendons, bursae, cartilage, erosions, hypoechoic rims around tendons and at joints were measured with regard to established standard scans. Mean, minimum, and maximum values, as well as two standard deviations (2 SD) were determined. Mean values +/-2 SD were defined as standard reference values.

RESULTS

Hypoechoic rims were normally present in joints and tendon sheaths owing to physiological synovial fluid and/or cartilage. Similarly, fluid was found in the subdeltoid bursa in 173/204 (85%), at the long biceps tendon in 56 (27%), in the suprapatellar recess in 158 (77%), in the popliteal bursae in 32 (16%), and in the retrocalcaneal bursa in 49 (24%). Erosions of >1 mm were seen at the humeral head in 47 (23%). Values for important intervals were determined. The correlation between two investigators was 0.96 (0.78-0.99). The reliability of follow up investigations was 0.83 (0.52-0.99).

CONCLUSIONS

Fluid in bursae as well as hypoechoic rims within joints and around tendons are common findings in healthy people. This study defines standard reference values for musculoskeletal ultrasonography to prevent misinterpretation of normal fluid as an anatomical abnormality.

Для цитирования: Schmidt W A, Schmidt H, Schicke B, Gromnica-Ihle E. Standard reference values for musculoskeletal ultrasonography.. Annals of the rheumatic diseases. 2004. DOI: 10.1136/ard.2003.015081.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.