MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jelectrocard.2024.05.097

Медицинская библиотека · Journal of electrocardiology · 2024

Postextrasystolic repolarization changes of ventricular premature beats correlate with structural heart disease and suggest prognostic implications.

Chen Xu-Miao, Wu Yang, Yu Jin, Wang Li-Chun

СтатьяПеревод в очереди

Аннотация

Ventricular premature beats (VPBs) can potentially lead to life-threatening arrhythmias, especially in patients with structural heart disease (SHD). However, identifying dangerous VPBs has always been a topic and challenge in clinical research. This study aimed to evaluate the relationship of postextrasystolic repolarization changes of VPBs with SHD and its possible additional prognostic value. 125 cases of frequent VPBs with SHD and 156 cases without SHD were included. VPBs were stratified selected from 24 h Holter recording according to the scale of heart rate. Average QTDV (difference value of QT interval between the first beat follow VPB with beats preceding VPB) and max QTDV were significantly longer in SHD group than that in the non-SHD group. For identifying patients with SHD, the best cutoff value were 19 ms for average QTDV (AUC = 0.931) and 29 ms for max QTDV (AUC = 0.910) respectively. For Tu morphology analysis, PT2 (postextrasystolic T wave amplitude change ≥2 mV), reversed T wave, and Pu (postextrasystolic u wave) change were all highly specific, but low sensitive as identification of SHD. Compared with average QTDV < 19 ms patients, average QTDV ≥ 19 ms patients had significantly larger left heart size and wores left cardiac function. The presence of non-persistent ventricular tachycardia runs was higher in average QTDV ≥ 19 ms group and positive Pu change group than that in control groups. The findings indicated that postextrasystolic repolarization changes of VPBs correlated with SHD and suggested potential value in prognosis asssessment.

Для цитирования: Chen Xu-Miao, Wu Yang, Yu Jin, Wang Li-Chun. Postextrasystolic repolarization changes of ventricular premature beats correlate with structural heart disease and suggest prognostic implications.. Journal of electrocardiology. 2024. DOI: 10.1016/j.jelectrocard.2024.05.097.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.