m+Medelevator.RU
← Поиск публикаций
Experimental physiology · 2025

Continuous carbon dioxide monitoring in the exhaled breath of mechanically ventilated rats.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wenzel Christin, Borgmann Silke, Flamm Bernd, Kuhn Lea, Schumann Stefan, Schmidt Johannes, Spaeth Johannes, Spassov Sashko

Аннотация

In small animals, carbon dioxide monitoring is either limited by the need to take blood samples for gas analysis, or it interferes with respiratory efficiency and lung mechanics analysis. We introduced a novel approach for continuous monitoring of CO2 in the expiratory limb of the breathing circuit. The relevance of the method is assessed by CO2 measurements at different respiratory settings. Rats were ventilated with a tidal volume (VT) of 8 mL kg-1. Respiratory rates were adjusted to achieve arterial CO2 partial pressure ( P aC O 2 ${P_{{\mathrm{aC}}{{\mathrm{O}}_2}}}$ ) between 35 and 45 mmHg. We measured partial pressure of CO2 in the expiratory limb of the breathing circuit (exCO2). exCO2 values were compared to P aC O 2 ${P_{{\mathrm{aC}}{{\mathrm{O}}_2}}}$ from blood gas analysis. The agreement between the two measurements was assessed by correlation and Bland-Altman analysis. The validity of the novel approach was established through additional experimental runs with VT of 7 or 6 mL kg-1, where the respiratory rate was set in accordance to exCO2. Measurements of exCO2 reflected P aC O 2 ${P_{{\mathrm{aC}}{{\mathrm{O}}_2}}}$ with high correlation (R2 = 0.8658). Bland-Altman analysis showed high agreement between the two measurements. Respiratory rate setting guided by exCO2 (39 ± 2 or 40 ± 2 mmHg during ventilation with VT of 7 or 6 mL kg-1, respectively) was appropriate to maintain P aC O 2 ${P_{{\mathrm{aC}}{{\mathrm{O}}_2}}}$ (41 ± 2 mmHg for both VT). Measurement of exCO2 provides a robust estimate of P aC O 2 ${P_{{\mathrm{aC}}{{\mathrm{O}}_2}}}$ in anaesthetized small animals during mechanical ventilation. Continuous monitoring of CO2 in the exhaled breath could be used to guide mechanical ventilation settings.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты