DOI 10.1016/j.jclinane.2011.04.005
Anesthesia management of totally endoscopic atrial septal defect repair with a robotic surgical system.
Аннотация
STUDY
OBJECTIVE
To investigate anesthetic techniques for robot-assisted endoscopic atrial septal defect (ASD) repair.
DESIGN
Clinical observational study.
SETTING
Operating room of a general military hospital.
PATIENTS: 56 adult, ASA physical status 1 and 2 patients undergoing elective general anesthesia.
INTERVENTIONS: After induction of general anesthesia, a left-sided, double-lumen endotracheal tube was positioned to allow single left-lung ventilation and contralateral CO(2) pneumothorax (capnothorax). With ultrasound guidance, peripheral cardiopulmonary bypass (CPB) catheters were placed.
MEASUREMENTS AND MAIN
RESULTS
All patients tolerated single left-lung ventilation before CPB; however, hypoxia (oxygen saturation < 90%) occurred in 11 (19.6%) patients post-CPB, which required treatment with continuous positive airway pressure. Fifteen (26.8%) patients had hypotension secondary to capnothorax, which was treated with transfusion and vasopressors. Aortic cross-clamp time was 43.6 ± 11.2 minutes, and CPB time was 106.7 ± 12.4 minutes. The median intensive care unit stay was 21 hours and postoperative hospital stay was 4 to 7 days.
CONCLUSIONS
The key issue for anesthetic management of robot-assisted totally endoscopic ASD repair is maintaining stable hemodynamics and oxygenation, especially during one-lung ventilation and capnothorax.