Comprehensive analysis of resting tremor based on acceleration signals of patients with Parkinson's disease.

Liu Sen, Yuan Han, Liu Jiali, Lin Hai, Yang Cuiwei, Cai Xiaodong

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Resting tremor is an essential characteristic in patients suffering from Parkinson's disease (PD).

OBJECTIVE

Quantification and monitoring of tremor severity is clinically important to help achieve medication or rehabilitation guidance in daily monitoring.

METHODS

Wrist-worn tri-axial accelerometers were utilized to record the long-term acceleration signals of PD patients with different tremor severities rated by Unified Parkinson's Disease Rating Scale (UPDRS). Based on the extracted features, three kinds of classifiers were used to identify different tremor severities. Statistical tests were further designed for the feature analysis.

RESULTS

The support vector machine (SVM) achieved the best performance with an overall accuracy of 94.84%. Additional feature analysis indicated the validity of the proposed feature combination and revealed the importance of different features in differentiating tremor severities.

CONCLUSION

The present work obtains a high-accuracy classification in tremor severity, which is expected to play a crucial role in PD treatment and symptom monitoring in real life.

Для цитирования: Liu Sen, Yuan Han, Liu Jiali, Lin Hai, Yang Cuiwei, Cai Xiaodong. Comprehensive analysis of resting tremor based on acceleration signals of patients with Parkinson's disease.. Technology and health care : official journal of the European Society for Engineering and Medicine. 2022. DOI: 10.3233/thc-213205.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.