MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00234-021-02782-z

Медицинская библиотека · Neuroradiology · 2021

Quantitative imaging features predict spinal tap response in normal pressure hydrocephalus.

Lotan Eyal, Damadian Brianna E, Rusinek Henry, Griffin Megan, Ades-Aron Benjamin, Lu Ning, Golomb James, George Ajax E

СтатьяПеревод в очереди

Аннотация

PURPOSE: Gait improvement following high-volume lumbar puncture (HVLP) and continuous lumbar drain (cLD) is widely used to predict shunt response in patients with suspected normal pressure hydrocephalus (NPH). Here, we investigate differences in MRI volumetric and traditional measures between HVLP/cLD responders and non-responders to identify imaging features that may help predict HVLP/cLD response.

METHODS

Eighty-two patients with suspected NPH were studied retrospectively. Gait testing was performed before and immediately/24 h/72 h after HVLP/cLD. A positive response was defined as improvement in gait post-procedure. Thirty-six responders (26 men; mean age 79.3 ± 6.3) and 46 non-responders (25 men; mean age 77.2 ± 6.1) underwent pre-procedure brain MRI including a 3D T1-weighted sequence. Subcortical regional volumes were segmented using FreeSurfer. After normalizing for total intracranial volume, two-way type III ANCOVA test and chi-square test were used to characterize statistical group differences. Evans' index, callosal angle (CA), and disproportionately enlarged subarachnoid space hydrocephalus were assessed. Multivariable logistic regression models were tested using Akaike information criterion to determine which combination of metrics most accurately predicts HVLP/cLD response.

RESULTS

Responders and non-responders demonstrated no differences in total ventricular and white/gray matter volumes. CA (men only) and third and fourth ventricular volumes were smaller; and hippocampal volume was larger in responders (p < 0.05). Temporal horns volume correlated with degree of improvement in gait velocity in responders (p = 0.0006). The regression model was 76.8% accurate for HVLP/cLD response.

CONCLUSION

CA and third and fourth ventricular volumes and hippocampal volume may serve as potentially useful imaging features that may help predict spinal tap response and hence potentially shunt response.

Для цитирования: Lotan Eyal, Damadian Brianna E, Rusinek Henry, Griffin Megan, Ades-Aron Benjamin, Lu Ning, Golomb James, George Ajax E. Quantitative imaging features predict spinal tap response in normal pressure hydrocephalus.. Neuroradiology. 2021. DOI: 10.1007/s00234-021-02782-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.