MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/lary.31634

Медицинская библиотека · The Laryngoscope · 2024

Safety of a Novel Upper Esophageal Sphincter Balloon Dilator.

Wandell Grace M, Swartwood Janeth Garcia, Brar Ashar Singh, Postma Gregory N, Belafsky Peter C

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

The shape of esophageal dilators has not changed in over 350 years. Clinical and animal research suggests that the upper esophageal sphincter (UES) is not round but approximates a kidney shape and that cylindrical dilators may be suboptimal. The Infinity UES Dilation System has been developed specifically for the anatomic configuration of the UES. This study evaluates the safety of the UES-specific Infinity Dilation System.

METHODS

All patients undergoing dilation of the UES between January 1, 2022 and September 1, 2023 were included. Demographics, procedure indication, dilator type, minor adverse events, and major complications were abstracted. Minor adverse events, complications, and maximum dilation dimension (mm) were compared between groups.

RESULTS

A total of 477 patients were included. Eight hundred and seventy-three total UES dilations were performed. The primary indications for UES dilation were cricopharyngeus muscle dysfunction (43%) and stenosis from radiation toxicity (40%). Twenty-three percent (202/873) of dilations were performed with an Infinity balloon, 31% (270/873) were performed using two conventional balloons placed side by side, and 46% (401/873) were performed with one singleton conventional balloon. The average maximum dilation dimension was 33 (±4.7) mm for Infinity balloons, 32 (±3.8) mm for two side-by-side balloons, and 18 (±3.4) mm for singleton balloons. There were three major complications with conventional balloons and none with Infinity balloons. There were no significant differences in minor adverse events between groups.

CONCLUSIONS

A UES-specific esophageal dilator provides a greater maximum dilation dimension and appears to be at least as safe as dilation with a single cylindrical balloon designed to dilate the esophagus.

LEVEL OF EVIDENCE: 3 Laryngoscope, 135:66-72, 2025.

Для цитирования: Wandell Grace M, Swartwood Janeth Garcia, Brar Ashar Singh, Postma Gregory N, Belafsky Peter C. Safety of a Novel Upper Esophageal Sphincter Balloon Dilator.. The Laryngoscope. 2024. DOI: 10.1002/lary.31634.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.