Medical Device-Related Pressure Injuries in Infants and Children.

Stellar Judith J, Hasbani Natalie R, Kulik Lindyce A, Shelley Stacey S, Quigley Sandy, Wypij David, Curley Martha A Q

СтатьяПеревод в очереди

Аннотация

PURPOSE: The purpose of this study was to describe medical device-related pressure injuries (MDRPIs) in hospitalized pediatric patients.

DESIGN

A prospective, descriptive study.

SAMPLE/SUBJECTS AND

SETTING

The sample comprised 625 patients cared for in 8 US pediatric hospitals. Participants were aged preterm to 21 years, on bed rest for at least 24 hours, and had a medical device in place.

METHODS

Two nursing teams, blinded to the other's assessments, worked in tandem to assess pressure injury risk, type of medical devices in use, and preventive interventions for each medical device. They also identified the presence, location, and stage of MDRPI. Subjects were observed up to 8 times over 4 weeks, or until discharge, whichever occurred first.

RESULTS

Of 625 enrolled patients, 42 (7%) developed 1 or more MDRPIs. Two-thirds of patients with MDRPIs were younger than 8 years. Patients experiencing MDRPIs had higher acuity scores on hospital admission, were more frequently cognitively and/or functionally impaired, or were extreme in body mass index. Respiratory devices caused the most injuries (6.19/1000 device-days), followed by immobilizers (2.40/1000 device-days), gastric tubes (2.24/1000 device-days), and external monitoring devices (1.77/1000 device-days). Of the 6336 devices in place, 36% did not have an MDRPI preventive intervention in place. Clinical variables contributing to MDRPI development included intensive care unit care (odds ratio [OR] 8.9, 95% confidence interval [CI] 1.9-43.6), use of neuromuscular blockade (OR 3.7, 95% CI 1.7-7.8), and inotropic/vasopressor medications (OR 2.7, 95% CI 1.7-4.3). Multivariable analysis indicated that Braden QD scores alone predicted MDRPI development.

CONCLUSION

Medical devices are common in hospitalized infants and children and these medical devices place patients at risk for MDRPI.

Для цитирования: Stellar Judith J, Hasbani Natalie R, Kulik Lindyce A, Shelley Stacey S, Quigley Sandy, Wypij David, Curley Martha A Q. Medical Device-Related Pressure Injuries in Infants and Children.. Journal of wound, ostomy, and continence nursing : official publication of The Wound, Ostomy and Continence Nurses Society. 2020. DOI: 10.1097/won.0000000000000683.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.