MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jccase.2011.03.005

Медицинская библиотека · Journal of cardiology cases · 2011

Retrograde fast pathway ablation with the EnSite NavX mapping system for slow-fast atrioventricular node reentrant tachycardia and a prolonged PR interval during sinus rhythm.

Sato Daisuke, Otani Hajime, Noda Teppei, Ueyama Takanao, Iwasaka Junji, Park Haengnam, Yamamoto Yoshihiro, Minato Naoki, Iwasaka Toshiji

СтатьяПеревод в очереди

Аннотация

An 84-year-old male had experienced palpitations. He was transported to our hospital for treatment of palpitations. A 12-lead electrocardiogram (ECG) showed regular tachycardia with a wide QRS complex of 153 bpm, and the P wave was not clear. The ECG after the tachycardia stopped showed a sinus rhythm, and there was a prolonged PR interval of 312 ms and complete right bundle branch block. We recorded a prolonged AH interval (235 ms) in electrophysiology study (EPS). As for the St-A interval (185 ms) by consecutive pacing from the right ventricular apex, it was short in comparison with the anterograde conduction. As a result of detailed EPS, we diagnosed the tachycardia as slow-fast atrioventricular nodal reentrant tachycardia. The anterograde conduction depended on the slow pathway (SP), and the fast pathway (FP) was considered to have only retrograde conduction. It was thought that a complete atrioventricular block been caused by the SP ablation. Therefore we carried out FP ablation with three-dimensional computed tomography and the EnSite NavX mapping system (St. Jude Medical, St Paul, MN, USA), which was superior in space resolution power, and were able to effect a radical cure without complications.

Для цитирования: Sato Daisuke, Otani Hajime, Noda Teppei, Ueyama Takanao, Iwasaka Junji, Park Haengnam, Yamamoto Yoshihiro, Minato Naoki, Iwasaka Toshiji. Retrograde fast pathway ablation with the EnSite NavX mapping system for slow-fast atrioventricular node reentrant tachycardia and a prolonged PR interval during sinus rhythm.. Journal of cardiology cases. 2011. DOI: 10.1016/j.jccase.2011.03.005.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.