MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/02184923251317753

Медицинская библиотека · Asian cardiovascular & thoracic annals · 2025

Bioprosthetic valve thrombosis developed shortly after aortic valve replacement.

Kuwano Akito, Yoshikai Masaru, Sato Hisashi

СтатьяКлинический случайПеревод в очереди

Аннотация

We present the case of an 83-year-old woman who presented with acute bioprosthetic valve thrombosis following surgical aortic valve replacement. On postoperative day 7, transthoracic echocardiography revealed reduced leaflet mobility in an implanted bioprosthetic valve, and contrast-enhanced computed tomography showed hypoattenuated leaflet thickening, leading to the diagnosis of prosthetic valve thrombosis. This case demonstrates that bioprosthetic valve thrombosis can occur even in the acute phase following surgical aortic valve replacement, highlighting the importance of early diagnosis and intervention. Close monitoring of leaflet mobility and thickening via transthoracic echocardiography is essential, with contrast-enhanced computed tomography serving as a valuable complementary tool.

Для цитирования: Kuwano Akito, Yoshikai Masaru, Sato Hisashi. Bioprosthetic valve thrombosis developed shortly after aortic valve replacement.. Asian cardiovascular & thoracic annals. 2025. DOI: 10.1177/02184923251317753.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.