Indian pediatrics · 2011
Echocardiographic parameters of patent ductus arteriosus in preterm infants.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Khositseth A, Nuntnarumit P, Chongkongkiat P
Аннотация
OBJECTIVE: To analyze cardiovascular parameters by echocardiography in preterm infants with patent ductus arteriosus (PDA).
SETTING: Tertiary-care pediatric university hospital.
DESIGN: Cross-sectional, hospital-based study.
PARTICIPANTS: 58 preterm infants, gestational age less than 33 weeks.
MEASUREMENTS: A complete 2-dimension, M-mode, color doppler echocardiography was performed in each preterm infant at approximately 48 hours of life.
RESULTS: Each preterm was categorized into hemodynamically significant PDA (hsPDA) (n=17, 29.3%), non-hemodynamically significant PDA (non-hsPDA) (n = 12, 20.7%), and no PDA (non-PDA) (n=29, 50%). Gestational age (29.4 ± 1.2 wk) and birth weight (1237 ± 358 g) of infants in hsPDA were significantly lower than those in non-PDA group (30.8 ± 1.3 wk, 1543 ± 361 g, P = 0.001), as compared to those in the non-hsPDA group (29.5 ± 2.3 wk, 1296 ± 462 g). Cardiovascular parameters including left atrium/aorta ratio, left atrium volume index, left ventricular dimensions and volumes, stroke volume, and cardiac output in hsPDA were significantly greater than those in non-hsPDA and nonPDA. LV systolic and diastolic functions were not significantly different in each group. LV global function in hsPDA (0.34 ± 0.13) was significantly lower than that in non-PDA (0.45 ± 0.13, P = 0.01).
CONCLUSIONS: In preterm infants with hsPDA, there was a volume load of the left heart causing increased stroke volume and cardiac output. The hsPDA could be detected by echocardiography even in the first 48 hours. The left atrial volume index may be a better indicator of the volume load of the heart.
SETTING: Tertiary-care pediatric university hospital.
DESIGN: Cross-sectional, hospital-based study.
PARTICIPANTS: 58 preterm infants, gestational age less than 33 weeks.
MEASUREMENTS: A complete 2-dimension, M-mode, color doppler echocardiography was performed in each preterm infant at approximately 48 hours of life.
RESULTS: Each preterm was categorized into hemodynamically significant PDA (hsPDA) (n=17, 29.3%), non-hemodynamically significant PDA (non-hsPDA) (n = 12, 20.7%), and no PDA (non-PDA) (n=29, 50%). Gestational age (29.4 ± 1.2 wk) and birth weight (1237 ± 358 g) of infants in hsPDA were significantly lower than those in non-PDA group (30.8 ± 1.3 wk, 1543 ± 361 g, P = 0.001), as compared to those in the non-hsPDA group (29.5 ± 2.3 wk, 1296 ± 462 g). Cardiovascular parameters including left atrium/aorta ratio, left atrium volume index, left ventricular dimensions and volumes, stroke volume, and cardiac output in hsPDA were significantly greater than those in non-hsPDA and nonPDA. LV systolic and diastolic functions were not significantly different in each group. LV global function in hsPDA (0.34 ± 0.13) was significantly lower than that in non-PDA (0.45 ± 0.13, P = 0.01).
CONCLUSIONS: In preterm infants with hsPDA, there was a volume load of the left heart causing increased stroke volume and cardiac output. The hsPDA could be detected by echocardiography even in the first 48 hours. The left atrial volume index may be a better indicator of the volume load of the heart.