Partial verification bias and incorporation bias affected accuracy estimates of diagnostic studies for biomarkers that were part of an existing composite gold standard.

Karch Annika, Koch Armin, Zapf Antonia, Zerr Inga, Karch André

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To investigate how choice of gold standard biases estimates of sensitivity and specificity in studies reassessing the diagnostic accuracy of biomarkers that are already part of a lifetime composite gold standard (CGS).

STUDY DESIGN AND

SETTING

We performed a simulation study based on the real-life example of the biomarker "protein 14-3-3" used for diagnosing Creutzfeldt-Jakob disease. Three different types of gold standard were compared: perfect gold standard "autopsy" (available in a small fraction only; prone to partial verification bias), lifetime CGS (including the biomarker under investigation; prone to incorporation bias), and "best available" gold standard (autopsy if available, otherwise CGS).

RESULTS

Sensitivity was unbiased when comparing 14-3-3 with autopsy but overestimated when using CGS or "best available" gold standard. Specificity of 14-3-3 was underestimated in scenarios comparing 14-3-3 with autopsy (up to 24%). In contrast, overestimation (up to 20%) was observed for specificity compared with CGS; this could be reduced to 0-10% when using the "best available" gold standard.

CONCLUSION

Choice of gold standard affects considerably estimates of diagnostic accuracy. Using the "best available" gold standard (autopsy where available, otherwise CGS) leads to valid estimates of specificity, whereas sensitivity is estimated best when tested against autopsy alone.

Для цитирования: Karch Annika, Koch Armin, Zapf Antonia, Zerr Inga, Karch André. Partial verification bias and incorporation bias affected accuracy estimates of diagnostic studies for biomarkers that were part of an existing composite gold standard.. Journal of clinical epidemiology. 2016. DOI: 10.1016/j.jclinepi.2016.03.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.