m+Medelevator.RU
← Поиск публикаций
Respiratory care · 2018

Incidence of Hypocapnia, Hypercapnia, and Acidosis and the Associated Risk of Adverse Events in Preterm Neonates.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Brown Melissa K, Poeltler Deborah M, Hassen Kasim O, Lazarus Danielle V, Brown Vanessa K, Stout Jeremiah J, Rich Wade D, Katheria Anup C

Аннотация

BACKGROUND: Permissive hypercapnia is a lung-protection strategy. We sought to review our current clinical practice for the range of permissive hypercapnia and identify the relationship between PaCO2 and pH and adverse outcomes.

METHODS: A secondary analysis of a delayed cord-clamping clinical trial was performed on all arterial blood gas tests in the first 72 h in infants < 32 weeks gestational age. All arterial blood gas values were categorized into a clinical range to determine the percent likelihood of occurring in the total sample. The univariate and multivariate relationships of severe adverse events and the time-weighted PaCO2 , fluctuation of PaCO2 , maximal and minimal PaCO2 , base excess, and pH were assessed.

RESULTS: 147 infants with birthweight of 1,206 ± 395 g and gestational age of 28 ± 2 weeks were included. Of the 1,316 total samples, < 2% had hypocapnia (PaCO2 <30 mm Hg), 47% were normocapnic (PaCO2 35-45 mm Hg), 26.5% had mild hypercapnia (PaCO2 45-55 mm Hg), 13% had moderate hypercapnia (PaCO2 55-65 mm Hg), and 6.5% had severe hypercapnia (PaCO2 ≥ 65 mm Hg). There were no adverse events associated with hypocapnia. Subjects with death/severe intraventricular hemorrhage had a higher mean PaCO2 of 52.3 versus 44.7 (odds ratio [OR] 1.16, 95% CI 1.04-1.29, P = .006), higher variability of PaCO2 with a standard deviation of 12.6 versus 7.8 (OR 1.15, 95% CI 1.03-1.27, P = .01), and a lower minimum pH of 7.03 versus 7.23 (OR 0, 95% CI 0-0.06, P = .003). There was no significant difference in any variables in subjects who developed other adverse events.

CONCLUSION: The routine targeting of higher than normal PaCO2 goals may lead to a low incidence of hypocapnia and associated adverse events. Hypercapnia is common, and moderate hypercapnia may increase the risk of neurologic injury and provide little pulmonary benefit.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты