Journal of vascular and interventional radiology : JVIR · 2019
Early Experience with the Covera Stent Graft as a Bridging Stent in Branched Thoraco-Abdominal Endovascular Aneurysm Repairs.
СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Gennai Stefano, Antonello Michele, Leone Nicola, Migliari Mattia, Andreoli Francesco, Dall'Antonia Alberto, Grego Franco, Silingardi Roberto
Аннотация
PURPOSE: To evaluate the Covera Plus (Bard, Tempe, Arizona) covered stent as a bridging stent in branched thoraco-abdominal endovascular aneurysm repair (BEVAR).
MATERIALS AND METHODS: Retrospective analysis of 112 self-expandable stents was performed at 2 university centers between August 2017 and March 2019. Thirty-one consecutive BEVAR procedures were studied (21 males; mean age, 75 years; 29 American Society of Anesthesiologists grade III/IV) with 119 patent target vessels (7 did not receive the studied device). Primary endpoints were technical success, branch instability, and primary/secondary clinical success. Secondary endpoints included primary/secondary patency and any adverse events.
RESULTS: Technical success was 100%. Median follow-up was 12 months (interquartile range, 6-14 months). Branch instability was registered twice (2/112), due to immediate renal occlusion and type Ic endoleak; no additional events occurred during the follow-up. Primary clinical success was 84%. There were 2 immediate deaths, 1 upper limb ischemia, 1 hemorrhage from splenic artery, and 1 type Ic endoleak; these last 3 events were successfully treated, with a secondary clinical success of 100% that was maintained during the follow-up. One late death occurred. Primary patency was 99% (111/112) and 100% (105/105) within 30 days and at the end of the study period,respectively. Adverse events included 4 acute kidney injuries and 2 spinal cord ischemia. No type I/III endoleaks, occlusion, fracture, or dislodging were diagnosed after 30 days.
CONCLUSIONS: The stent graft seems safe and effective for bridging in BEVAR with low branch instability and high patency rate. Longer follow-up is required to confirm these promising results.
MATERIALS AND METHODS: Retrospective analysis of 112 self-expandable stents was performed at 2 university centers between August 2017 and March 2019. Thirty-one consecutive BEVAR procedures were studied (21 males; mean age, 75 years; 29 American Society of Anesthesiologists grade III/IV) with 119 patent target vessels (7 did not receive the studied device). Primary endpoints were technical success, branch instability, and primary/secondary clinical success. Secondary endpoints included primary/secondary patency and any adverse events.
RESULTS: Technical success was 100%. Median follow-up was 12 months (interquartile range, 6-14 months). Branch instability was registered twice (2/112), due to immediate renal occlusion and type Ic endoleak; no additional events occurred during the follow-up. Primary clinical success was 84%. There were 2 immediate deaths, 1 upper limb ischemia, 1 hemorrhage from splenic artery, and 1 type Ic endoleak; these last 3 events were successfully treated, with a secondary clinical success of 100% that was maintained during the follow-up. One late death occurred. Primary patency was 99% (111/112) and 100% (105/105) within 30 days and at the end of the study period,respectively. Adverse events included 4 acute kidney injuries and 2 spinal cord ischemia. No type I/III endoleaks, occlusion, fracture, or dislodging were diagnosed after 30 days.
CONCLUSIONS: The stent graft seems safe and effective for bridging in BEVAR with low branch instability and high patency rate. Longer follow-up is required to confirm these promising results.
Предметные рубрики MeSH
AgedAlloysAortic Aneurysm, ThoracicBlood Vessel ProsthesisBlood Vessel Prosthesis ImplantationEndovascular ProceduresFemaleHumansItalyMalePostoperative ComplicationsProsthesis DesignRetreatmentRetrospective StudiesRisk FactorsSelf Expandable Metallic StentsTime FactorsTreatment OutcomeVascular Patency