MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12639-018-0996-9

Медицинская библиотека · Journal of parasitic diseases : official organ of the Indian Society for Parasitology · 2018

Bioinformatics analysis of single and multi-hybrid epitopes of GRA-1, GRA-4, GRA-6 and GRA-7 proteins to improve DNA vaccine design against Toxoplasma gondii.

Kim Hyojung, Gook Joonhee, Jeong Seokkyu, Kim Jeonghoon, Lee Hyunjong, Hyun Seung Hyup, Cho Young Seok, Choi Joon Young, Lee Kyung-Han, Moon Seung Hwan

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: Endothelial dysfunction is an early risk marker of cardiovascular disease in diabetes mellitus. Timely screening is important in reducing cardiovascular disease-associated morbidity and mortality. This cross-sectional study investigates the acceptability and preferability of non-invasive cardiovascular risk procedures (EndoPAT2000 system and the ECG-gated fundoscope) in participants with diabetes mellitus compared to controls.

METHODS

A self-administered Likert scale-based questionnaire was completed by 106 controls and 117 participants with diabetes mellitus, identified through stratified random sampling, upon conclusion of an Australian Heart Eye sub-study conducted at Westmead Hospital, NSW, Australia from 2012 to 2014. Pearson's χ 2 test, independent-samples t-test and regression analysis were performed.

RESULTS

Study participants who responded to the questionnaire had no preference for procedures (controls: 2.4 ± 1.1 vs diabetes mellitus: 2.5 ± 0.9, p = 0.38) but had an overall more negative experience with most aspects of the ECG-gated fundoscope than the EndoPAT2000 system. Of those with diabetes mellitus, participants who provided poorer self-rated health expressed discomfort with the mydriatic drops (ß 0.27, 95%CI 0.001 - 0.54, p = 0.049) and the fundoscope's green light filter (ß 0.27, 95%CI 0.07 - 0.47, p = 0.009), as well as maintaining still (ß 0.40, 95%CI 0.08 - 0.72, p = 0.02) and not blinking (ß 0.38, 95%CI 0.07 - 0.70, p = 0.02) during photo acquisition. These participants were also less willing to repeat the ECG-gated fundoscope procedure (ß 0.29, 95%CI 0.07 - 0.52, p = 0.01).

CONCLUSIONS

Participants with diabetes mellitus, especially with poorer self-rated health, had a more negative experience with the ECG-gated fundoscope than the EndoPAT2000 system. Difficulties experienced under examination by the ECG-gated fundoscope appear related to the procedural design, which requires amendments improving patient comfort and compliance.

Для цитирования: Kim Hyojung, Gook Joonhee, Jeong Seokkyu, Kim Jeonghoon, Lee Hyunjong, Hyun Seung Hyup, Cho Young Seok, Choi Joon Young, Lee Kyung-Han, Moon Seung Hwan. Bioinformatics analysis of single and multi-hybrid epitopes of GRA-1, GRA-4, GRA-6 and GRA-7 proteins to improve DNA vaccine design against Toxoplasma gondii.. Journal of parasitic diseases : official organ of the Indian Society for Parasitology. 2018. DOI: 10.1007/s12639-018-0996-9.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.