m+Medelevator.RU
← Поиск публикаций
Food science and biotechnology · 2026

Effects of curcumin and storage temperature on chia oil-beeswax oleogel as a fat replacer in model chicken sausage.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Das Ashesh, Gupta Aarushi, Ramamoorthy Lakshiya, Benjamin Neo Zhong Yi, Agrawat Deepanshu, Pandit Moitreyo, Khawar M Muneeb, Chilaka Chika, Nyirahabimana Delphine, Goraga Biruk, Rehman Muhammad Abdur, Yathindra Meenakshi Reddy, Khawar Muneeb

Аннотация

UNLABELLED: This meta-analysis compared peri-procedural and short-term outcomes of transcatheter aortic valve replacement (TAVR) versus surgical aortic valve replacement (SAVR) in severe bicuspid aortic valve (BAV) stenosis, addressing TAVR's debated efficacy in this context. A systematic search of PubMed, ScienceDirect, and Embase up to January 2025. Pooled odds ratios (ORs) with 95% confidence intervals (CIs) were calculated using a random-effects model. Heterogeneity was assessed with the I2 statistic, with p < 0.05 as significant. 9 observational studies and 1 randomized controlled trial with 148,771 patients (TAVR: 16,584; SAVR: 132,187) were included. TAVR showed lower odds of acute kidney injury (OR = 0.58, 95% CI: 0.35-0.97; p = 0.04), major bleeding (OR = 0.29, 95% CI: 0.12-0.69; p = 0.005), and pulmonary complications (OR = 0.44, 95% CI: 0.34-0.57; p < 0.00001) versus SAVR. However, TAVR increased risks of paravalvular leak (OR = 2.15, 95% CI: 1.20-3.88; p = 0.01) and permanent pacemaker implantation (OR = 2.08, 95% CI: 1.39-3.10; p = 0.0004). No significant differences were noted in in-hospital mortality (OR = 1.04, 95% CI: 0.56-1.94; p = 0.89), stroke (OR = 1.05, 95% CI: 0.86-1.28; p = 0.65), or vascular complications (OR = 0.67, 95% CI: 0.18-2.52; p = 0.55). TAVR reduces risks of acute kidney injury, major bleeding, and pulmonary complications in BAV stenosis but raises paravalvular leak and pacemaker implantation risks compared to SAVR. Mortality and stroke rates are similar. TAVR may suit selected patients, but long-term data is needed.

SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12055-025-02146-9.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты