Four-Point Flange Intrascleral Fixation With Double Suture Through the Dislocated Plate-Haptic Trifocal Intraocular Lens.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Wang Yong, Zhou Li, Bao Xianyi, Peng Tingting, Lei Rong, Ortega-Usobiaga Julio
Аннотация
PURPOSE: To describe a technique for the replacement of dislocation of plate-haptic trifocal intraocular lens (IOL) through double-suture 4-point flange intrascleral fixation.
DESIGN: Retrospective, interventional, noncomparative, case series.
METHODS: A total of 7 eyes of 7 patients with a dislocated plate-haptic trifocal IOL were enrolled for 4-point flange intrascleral fixation with double 7-0 polypropylene suture. Preoperative and postoperative visual acuity, operating time, refractive results, postoperative IOL tilt and decentration, and intraoperative and postoperative complications were recorded.
RESULTS: The mean postoperative uncorrected distance visual acuity (UDVA) was 0.05 ± 0.06 logarithm of the minimum angle of resolution (logMAR). The mean postoperative uncorrected intermediate visual acuity (UIVA) at 80 cm was 0.09 ± 0.06 logMAR and the mean postoperative uncorrected near visual acuity (UNVA) at 40 cm was 0.06 ± 0.07 logMAR. The mean postoperative residual spherical equivalent values were -0.27 ± 0.39 diopters. The visual function index-14 questionnaire showed that no difficulty was found in >80% of subjects for all tasks. The mean surgical time was 16.23 ± 5.64 min. The mean tilt of IOL was 3.74° ± 1.31° and the mean decentration of the IOL was 0.18 ± 0.09 mm. No important complications appeared.
CONCLUSION: We have described the technique of 4-point flange intrascleral fixation for plate-haptic trifocal IOL.
DESIGN: Retrospective, interventional, noncomparative, case series.
METHODS: A total of 7 eyes of 7 patients with a dislocated plate-haptic trifocal IOL were enrolled for 4-point flange intrascleral fixation with double 7-0 polypropylene suture. Preoperative and postoperative visual acuity, operating time, refractive results, postoperative IOL tilt and decentration, and intraoperative and postoperative complications were recorded.
RESULTS: The mean postoperative uncorrected distance visual acuity (UDVA) was 0.05 ± 0.06 logarithm of the minimum angle of resolution (logMAR). The mean postoperative uncorrected intermediate visual acuity (UIVA) at 80 cm was 0.09 ± 0.06 logMAR and the mean postoperative uncorrected near visual acuity (UNVA) at 40 cm was 0.06 ± 0.07 logMAR. The mean postoperative residual spherical equivalent values were -0.27 ± 0.39 diopters. The visual function index-14 questionnaire showed that no difficulty was found in >80% of subjects for all tasks. The mean surgical time was 16.23 ± 5.64 min. The mean tilt of IOL was 3.74° ± 1.31° and the mean decentration of the IOL was 0.18 ± 0.09 mm. No important complications appeared.
CONCLUSION: We have described the technique of 4-point flange intrascleral fixation for plate-haptic trifocal IOL.
Предметные рубрики MeSH
HumansRetrospective StudiesScleraVisual AcuitySuture TechniquesMaleFemaleLens Implantation, IntraocularAgedArtificial Lens Implant MigrationMiddle AgedSuturesMultifocal Intraocular LensesRefraction, OcularPolypropylenesPostoperative ComplicationsPhacoemulsificationAged, 80 and overLenses, IntraocularProsthesis Design