Indian journal of orthopaedics · 2015
Safe corridors for K-wiring in phalangeal fractures.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Rex C, Vignesh R, Javed M, Balaji Subba Chandra, Premanand C, Zakki Syed Ashfaque
Аннотация
BACKGROUND: Unstable phalangeal fractures are commonly treated with K-wire fixation. Operative fixation must be used judiciously and with the expectation that the ultimate outcome should be better than the outcome after nonoperative management. It is necessary to achieve a stable fracture fixation and early mobilization. In order to achieve this goal, one should closely understand the safe portals/corridors in hand for K-wire entry for fractures of the phalanges. Safe corridors were defined and tested using a pilot cadaveric and a clinical case study by assessing the outcome.
MATERIALS AND METHODS: In our prospective case series, 50 patients with 64 phalangeal fractures were treated with closed reduction and K-wires were inserted through safe portals identified by a pilot cadaveric study. On table active finger movement test was done and the results were analyed using radiology, disabilities of the arm, shoulder, and hand (DASH) score and total active motion (TAM). In our study, little finger (n = 28) was the most commonly involved digit. In fracture pattern, transverse (n = 20) and spiral (n = 20) types were common. Proximal phalanx (n = 38) was commonly involved and the common site being the base of the phalanx (n = 28).
RESULTS: 47 (95%) patients had excellent TAM and the mean postoperative DASH score was 58.05. All patients achieved excellent and good scores proving the importance of the safe corridor concept.
CONCLUSION: K-wiring through the safe corridor has proved to yield the best clinical results because of least tethering of soft tissues as evidenced by performing "on-table active finger movement test" at the time of surgery. We strongly recommend K-wiring through safe portals in all phalangeal fractures.
MATERIALS AND METHODS: In our prospective case series, 50 patients with 64 phalangeal fractures were treated with closed reduction and K-wires were inserted through safe portals identified by a pilot cadaveric study. On table active finger movement test was done and the results were analyed using radiology, disabilities of the arm, shoulder, and hand (DASH) score and total active motion (TAM). In our study, little finger (n = 28) was the most commonly involved digit. In fracture pattern, transverse (n = 20) and spiral (n = 20) types were common. Proximal phalanx (n = 38) was commonly involved and the common site being the base of the phalanx (n = 28).
RESULTS: 47 (95%) patients had excellent TAM and the mean postoperative DASH score was 58.05. All patients achieved excellent and good scores proving the importance of the safe corridor concept.
CONCLUSION: K-wiring through the safe corridor has proved to yield the best clinical results because of least tethering of soft tissues as evidenced by performing "on-table active finger movement test" at the time of surgery. We strongly recommend K-wiring through safe portals in all phalangeal fractures.