STUDY

OBJECTIVE

To determine if a lower than previously reported oral-transdermal clonidine regimen could reduce postoperative morphine requirements without producing systemic side effects.

DESIGN

Double-blind, randomized, placebo-controlled study.

SETTING

University-affiliated hospital.

PATIENTS: 29 healthy, ASA physical status I and II females undergoing elective abdominal hysterectomy.

INTERVENTIONS: Patients received preoperative oral clonidine 4 to 5 mu/kg and a 7 cm2 transdermal clonidine patch (0.2 mg/24 hours) or a placebo tablet and patch.

MEASUREMENTS AND MAIN

RESULTS

Postoperative patient-controlled analgesia pumps provided morphine during the 48-hour study period. Morphine use, hemodynamic changes, and nonhemodynamic side effects were recorded. Additionally, visual analog pain scales (VAPS) and plasma concentrations of morphine and clonidine were measured. We found that low-dose clonidine had no potentiating effect on morphine analgesia. Postoperative morphine use, VAPS, and morphine plasma levels were similar between the control and clonidine-treated groups. Nevertheless, patients in the clonidine group experienced a significantly greater incidence of intraoperative and postoperative hypotension and bradycardia than did the control group. No differences were noted in the incidence of nonhemodynamic side effects.

CONCLUSIONS

The low-dose oral-transdermal clonidine regimen evaluated failed to reduce postoperative morphine requirements, although patients who received clonidine were still at risk for developing hypotension.

Для цитирования: Owen M D, Fibuch E E, McQuillan R, Millington W R. Postoperative analgesia using a low-dose, oral-transdermal clonidine combination: lack of clinical efficacy.. Journal of clinical anesthesia. 1997. DOI: 10.1016/s0952-8180(96)00218-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.