Аннотация

BACKGROUND

Knowledge of coronary sinus (CS) anatomy and its variations is one of the important factors determining the final position of left ventricle pacing lead during cardiac resynchronization therapy.

METHODS

Coronary venous system anatomy, including number, diameter, and opening angles of tributaries, was studied in 50 normal formalin-fixed adult cadaveric hearts.

RESULTS

Thebesian valve (TV) and Vieussens valve were present in 64% and 60% cases, respectively. CS ostium coverage of ≥75% by TV was seen in 25% (8/32) cases. Number of prominent tributaries lying between anterior interventricular vein and middle cardiac vein varied from 1-4. In 28% of hearts, only one prominent tributary was present. Midlateral vein (average diameter 1.75 ± 0.66 mm) with an average distance of 43.5 ± 12.2 mm from coronary ostium was present in 58% (29/50) hearts, of which it formed an acute angle with CS axis in four (13.39%) cases. Posterolateral vein (average diameter 1.62 ± 0.45 mm) with an average distance of 33.4 ± 11.7 mm from coronary ostium was found in 72% (36/50) cases and formed an acute angle with CS in three (8.33%) cases.

CONCLUSIONS

Restrictive TV covering ≥75% CS ostium (25% cases), presence of single prominent tributary (28% cases), and formation of acute angle of tributary with CS axis (1/4 cases with anterolateral vein, 4/29 cases with midlateral vein, 3/36 cases with posterolateral vein, and 3/28 cases with posterior veins of the left ventricle) can impede successful cannulation of CS.

Для цитирования: Randhawa Arpandeep, Saini Abhimanyu, Aggarwal Anjali, Rohit Manoj K, Sahni Daisy. Variance in coronary venous anatomy: a critical determinant in optimal candidate selection for cardiac resynchronization therapy.. Pacing and clinical electrophysiology : PACE. 2012. DOI: 10.1111/pace.12026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.