MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12013-011-9246-9

Медицинская библиотека · Cell biochemistry and biophysics · 2011

Porcine model of congenital heart defect with decreased pulmonary blood flow.

Xuegang Liu, Chao Shi, Kangwu Wang, Yiyao Liu, Guixin Duan, Xiaohong Li, Wei Song, Junxiang Zhang

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A porcine model was produced to study the pathophysiology of congenital heart defect (CHD) with decreased pulmonary blood flow. Twenty piglets (1-2 months) were randomly divided as mild to moderate stenosis/T(1) group (n = 7) in which artificial atrial septal defect (ASD) with pulmonary artery banding generated a systolic pressure gradient of 20-30 mmHg; severe stenosis/T group (n = 7) group with a systolic pressure gradient of ≥30-50 mmHg; and controls/C group (n = 6) underwent sham surgery. At 1 month postoperatively, 64-slice computed tomography (CT) was performed. At 2 months, left-chest surgery was performed to measure ASD diameter, arterial blood gas, hemoglobin, and Trans-PABP. Our data show successful establishment of porcine CHD model. ASDs in T(1)/T(2) groups were 8.0 ± 0.5/8.9 ± 1.4 mm, respectively. Trans-PABP showed that the pressure increase in T(2) was higher (P < 0.01) than in T(1) group. Arterial blood PaO(2) and SaO(2) of T(1/)T(2) groups were significantly lower than controls. AoD was significantly lower in T(1) than in C group. Balloon dilation was significantly lower than AoD in T(1)/T(2) groups. Besides, one animal in T(1), two animals in T(2) ,and one animal in C group died. We conclude that ASD with pulmonary artery banding is a successful intervention to establish such a model, and our findings may influence the treatment of patients with similar heart disease.

Для цитирования: Xuegang Liu, Chao Shi, Kangwu Wang, Yiyao Liu, Guixin Duan, Xiaohong Li, Wei Song, Junxiang Zhang. Porcine model of congenital heart defect with decreased pulmonary blood flow.. Cell biochemistry and biophysics. 2011. DOI: 10.1007/s12013-011-9246-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.