MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12871-022-01800-8

Медицинская библиотека · BMC anesthesiology · 2022

Trachway® flexible stylet facilitates the correct placement of double-lumen endobronchial tube: a prospective, randomized study.

Hsu Hung-Te, Kuo Yi-Wei, Ma Chao-Wei, Su Miao-Pei, Tseng Kuang-Yi, Li Chin-Ling, Cheng Kuang-I

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The mainstream facilitation of one-lung ventilation is using double-lumen endobronchial tubes. However, it is more difficult to be positioned properly and more likely to cause airway injuries. How to place double-lumen endobronchial tubes rapidly and correctly is important for thoracic anesthesiologists.

METHODS

One hundred eight patients with an American Society of Anesthesiologists physical status of I to III were 20 years of age or over, and required one-lung ventilation for thoracic surgery. They were randomly assigned to the conventional technique group (n = 36), the flexible fiberoptic bronchoscopy group (n = 36), or the Trachway® flexible stylet group (n = 36). The primary endpoint was the time needed for intubation. T1, the time from the tip of the blade passing between the patient's lips to identification of the vocal cords; and T2, the time from identification of the vocal cords to the bronchial lumen was in the correct position.

RESULTS

T1 had no significant difference between groups, but T2 was significantly shorter in the Trachway® flexible stylet group (p < 0.0001) and longer in the conventional technique group (p < 0.0001).

CONCLUSIONS

Using Trachway® flexible stylet for correct placement of double-lumen endobronchial tubes not only significantly shortened the intubation time, but also reduced incidence of carinal injuries. It is an alternative, and a choice with good safety.

TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02364622, 18/02/2015, Retrospectively registered.

Для цитирования: Hsu Hung-Te, Kuo Yi-Wei, Ma Chao-Wei, Su Miao-Pei, Tseng Kuang-Yi, Li Chin-Ling, Cheng Kuang-I. Trachway® flexible stylet facilitates the correct placement of double-lumen endobronchial tube: a prospective, randomized study.. BMC anesthesiology. 2022. DOI: 10.1186/s12871-022-01800-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.