MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.iccn.2024.103800

Медицинская библиотека · Intensive & critical care nursing · 2024

Decibel level of coughing as a predictor of extubation outcome in mechanically ventilated intensive care patients: A prospective, observational study.

Li Huan, Zhou Tiantian, Ni Haibin, Wang Tingting, Wei Yanli, Huang Xiaofei, Lyu Jian

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

AIM: This study aims to evaluate the feasibility and clinical utility of measuring cough decibel level as predictive markers for extubation outcomes in mechanically ventilated patients.

DESIGN

A prospective observational study.

SETTING

Three interdisciplinary medical-surgical intensive care units across China.

MAIN OUTCOME MEASURES: The primary outcomes assessed were extubation results in patients. Secondary measures included the cough decibel level, semiquantitative cough intensity scores, and white card test results recorded prior to extubation.

RESULTS

A total of 71 patients were included, 55 patients were in the extubation success group and 16 in the failure group. The mean age was 78(71,83) years, mainly male (73.2 %). Despite the baseline characteristics being mostly consistent across both groups, significant differences were noted in duration of mechanical ventilation, and intensive care units and hospital stay. Remarkably, the cough decibel was substantially lower in the extubation failure group compared to the other group (78.69 ± 8.23 vs 92.28 ± 7.01 dB). The Receiver Operating Characteristic curve analysis revealed that a cough decibel below 85.77 dB is the optimal threshold for predicting extubation failure, exhibiting an 80 % sensitivity and 91.67 % specificity.

CONCLUSION

The study corroborates that the cough decibel level serves as a quantifiable metric in patients undergoing mechanical ventilation. It posits that the likelihood of extubation failure escalates when the cough decibel falls below 85.77 dB.

IMPLICATIONS FOR CLINICAL PRACTICE: Quantification of coughing capacity in decibels may be a good predictor of extubation outcome, thus offering assistance to healthcare professionals in evaluating the readiness of patients for extubation.

Для цитирования: Li Huan, Zhou Tiantian, Ni Haibin, Wang Tingting, Wei Yanli, Huang Xiaofei, Lyu Jian. Decibel level of coughing as a predictor of extubation outcome in mechanically ventilated intensive care patients: A prospective, observational study.. Intensive & critical care nursing. 2024. DOI: 10.1016/j.iccn.2024.103800.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.