Nederlands tijdschrift voor geneeskunde · 1996
[Digital roentgen-guided large-needle biopsy as an alternative to surgical biopsy in patients with nonpalpable mammographic abnormalities].
Сравнительное исследованиеАннотация на английскомСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Pijnappel R M, de Graaf P W, van Dalen A, Hennipman A, van den Tweel J G, Mali W P
Аннотация
OBJECTIVE: To compare histopathological findings from stereotaxic needle core biopsies and from excision biopsies performed on patients with impalpable breast lesions suggestive of carcinoma.
DESIGN: Prospective and descriptive, with a description of the stereotaxic needle core biopsy procedure.
SETTING: Academic Hospital Utrecht, the Netherlands.
METHODS: In 36 patients core biopsies were done with 14-gauge biopsy needles, followed by a localisation procedure with surgical biopsy. The pathological features of the core and excision specimens were compared.
RESULTS: Results of 35 (97%) core biopsies corresponded to those of excision biopsies. Stereotaxic core biopsy was not possible due to technical problems in 2 cases.
CONCLUSION: Stereotaxic core biopsy appears to be an acceptable alternative to excision biopsy.
DESIGN: Prospective and descriptive, with a description of the stereotaxic needle core biopsy procedure.
SETTING: Academic Hospital Utrecht, the Netherlands.
METHODS: In 36 patients core biopsies were done with 14-gauge biopsy needles, followed by a localisation procedure with surgical biopsy. The pathological features of the core and excision specimens were compared.
RESULTS: Results of 35 (97%) core biopsies corresponded to those of excision biopsies. Stereotaxic core biopsy was not possible due to technical problems in 2 cases.
CONCLUSION: Stereotaxic core biopsy appears to be an acceptable alternative to excision biopsy.