MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.12000

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2012

Coronary venous retention-a feature in heart failure as evidenced by mean of cardiac computed tomography.

Mlynarska Agnieszka, Mlynarski Rafal, Sosnowski Maciej

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Whether the functional status of the heart can influence the coronary venous system itself has not yet been examined. In order to answer this question, we used multislice computed tomography (CT) imaging.

PURPOSE: To answer the question of whether the heart failure (HF) is associated with significant anatomical changes in the coronary venous system?

METHODS

In 136 (aged 56.6 ± 11.5) patients, a 64-slice CT was performed. Patients were divided into three groups according their ejection fraction. In each case, nine 3D volume rendering reconstructions, using a 2-mm layer with electrocardiographic-gating, were created at 0% to 90% R-R intervals (step 10%). The visualization of coronary veins (CVs) was graded independently by two experts trained in multislice computed tomography on a 0-5 point scale (0-not visible/lack of vein; 5-smoothly bordered vascular structure).

RESULTS

The average number of visible CVs per case was 3.44 in the HF group and 2.72 in patients with a normal ejection fraction (P = 0.0246). The statistical correlation between a reduction in ejection fraction and the increase in the number of veins was found (r =-0.2446, P < 0.05). For two of seven common variants of the coronary venous system at least two target veins (posterolateral and lateral) for cardiac resynchronization were presented.

CONCLUSIONS

The statistically higher number of veins in patients with heart failure may suggest an association between a failing heart and cardiac venous retention.

Для цитирования: Mlynarska Agnieszka, Mlynarski Rafal, Sosnowski Maciej. Coronary venous retention-a feature in heart failure as evidenced by mean of cardiac computed tomography.. Pacing and clinical electrophysiology : PACE. 2012. DOI: 10.1111/pace.12000.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.