MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00270-019-02244-3

Медицинская библиотека · Cardiovascular and interventional radiology · 2019

Distal Edge Stenosis After Stent Placement for Isolated Superior Mesenteric Artery Dissection: Mechanisms and Risk Factor Analysis.

Hang Cheng, Chen Wenhua, Su Haobo, Jia Zhongzhi, Qi Chunjian, Gu Jianping

СтатьяПеревод в очереди

Аннотация

PURPOSE: To analyze factors potentially associated with the occurrence of distal edge stenosis after stent placement for isolated superior mesenteric artery dissection (ISMAD).

MATERIALS AND

METHODS

Cases of consecutive patients who were diagnosed with spontaneous ISMAD between February 2010 and July 2018 were retrospectively identified. Of the 123 cases identified, 45 patients (42 men; three women) underwent endovascular stent placement and were included in the study. Univariate and multivariate analyses were used to assess factors potentially associated with distal edge stenosis.

RESULTS

The technical success rate among study patients was 100%. During 26.7 ± 17.3 months of follow-up, CT angiography demonstrated good distal edge patency in 25 patients (55.6%) and evidence of distal edge stenosis in 20 patients (44.4%). In univariate analysis, stent length (odds radio [OR] 1.03; 95% confidence interval [CI] 1.01, 1.06; P = .02), stent-to-vessel (S/V) diameter ratio (OR 2.27; 95% CI 1.35, 3.82; P < .01), and angulation at the distal edge (OR 1.05; 95% CI 1.00, 1.10; P =.03) were significantly associated with distal edge stenosis; only S/V diameter ratio (OR 3.36; 95% CI 1.41, 7.99; P < .01) and angulation at the distal edge (OR 1.12; 95% CI 1.01, 1.23; P =.03) retained this significance in multivariate analysis.

CONCLUSIONS

Distal edge stenosis after stent placement for ISMAD is common. S/V diameter ratio and angulation at the distal edge are independent risk factors for distal edge stenosis in patients with ISMAD who undergo stent placement.

Для цитирования: Hang Cheng, Chen Wenhua, Su Haobo, Jia Zhongzhi, Qi Chunjian, Gu Jianping. Distal Edge Stenosis After Stent Placement for Isolated Superior Mesenteric Artery Dissection: Mechanisms and Risk Factor Analysis.. Cardiovascular and interventional radiology. 2019. DOI: 10.1007/s00270-019-02244-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.