Safety, efficacy, and reliability evaluation ofa novel small-diameter defibrillation lead: Global LEADR pivotal trial results.

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Crossley George H, Sanders Prashanthan, Hansky Bert, De Filippo Paolo, Shah Maully J, Shoda Morio, Khelae Surinder Kaur, Richardson Travis D, Philippon François, Zakaib John S, Tse Hung-Fat, Sholevar Darius P, Stellbrink Christoph, Pathak Rajeev K, Milašinović Goran, Chinitz Jason S, Tsang Bernice, West Michael B, Ramza Brian M, Han Xuebin, Bozorgnia Babak, Carta Roberto, Geelen Tessa, Himes Adam K, Platner Megan L, Thompson Amy E, Mason Pamela K, Lead EvaluAtion for Defibrillation and Reliability Trial Investigators

Аннотация

BACKGROUND: Implantable cardioverter-defibrillators last longer, and interest in reliable leads with targeted lead placement is growing. The OmniaSecure defibrillation lead is a novel, small-diameter, catheter-delivered lead designed for targeted placement, based on the established SelectSecure SureScan MRI Model 3830 lumenless pacing lead platform.

OBJECTIVE: This trial assessed safety and efficacy of the OmniaSecure defibrillation lead.

METHODS: The worldwide LEADR pivotal clinical trial enrolled patients indicated for de novo implantation of a primary or secondary prevention implantable cardioverter-defibrillator or cardiac resynchronization therapy defibrillator, all of whom received the study lead. The primary efficacy end point was successful defibrillation at implantation per protocol. The primary safety end point was freedom from study lead-related major complications at 6 months. The primary efficacy and safety objectives were met if the lower bound of the 2-sided 95% credible interval was >88% and >90%, respectively.

RESULTS: In total, 643 patients successfully received the study lead, and 505 patients have completed 12-month follow-up. The lead was placed in the desired right ventricular location in 99.5% of patients. Defibrillation testing at implantation was completed in 119 patients, with success in 97.5%. The Kaplan-Meier estimated freedom from study lead-related major complications was 97.1% at 6 and 12 months. The trial exceeded the primary efficacy and safety objective thresholds. There were zero study lead fractures and electrical performance was stable throughout the mean follow-up of 12.7 ± 4.8 months (mean ± SD).

CONCLUSION: The OmniaSecure lead exceeded prespecified primary end point performance goals for safety and efficacy, demonstrating high defibrillation success and a low occurrence of lead-related major complications with zero lead fractures.