Аннотация

OBJECTIVES

To assess the efficacy, safety and, thus, advantages and disadvantages, of early postplacental intrauterine device (IUD) insertion.

METHODS

IUDs were inserted within 10 min after postplacental expulsion in term pregnancy both in vaginal and cesarean deliveries via a ring forceps. Of the 276 patients enrolled, 235 were included in the study. Recipients were scheduled for examination before hospital discharge and at 6 weeks, 6 months and 12 months after postplacental insertion.

RESULTS

The percentages of women returning for a follow-up visit were 221 (94%), 210 (89%) and 183 (78%) at 6 weeks, 6 months and 12 months, respectively. Among IUD acceptors, 74% of the cases had vaginal deliveries and 26% had cesarean deliveries. Continuation rates were relatively high, 87.6% and 76.3%, at 6 and 12 months, respectively, after postplacental insertion of IUD. In this study, the 1-year cumulative expulsion rate with TCu 380A device was 12.3%, which may be regarded as a standard expulsion rate for immediate postplacental insertion of similar models of IUDs.

CONCLUSION

The evidence from this study suggests that immediate postplacental insertion of CuT 380 models is an effective, useful, safe, convenient and low-cost procedure for early postpartum contraception.

Для цитирования: Celen Sevki, Möröy Perran, Sucak Ayhan, Aktulay Ayla, Danişman Nuri. Clinical outcomes of early postplacental insertion of intrauterine contraceptive devices.. Contraception. 2004. DOI: 10.1016/j.contraception.2003.12.004.