DOI 10.1002/acm2.70229

Медицинская библиотека · Journal of applied clinical medical physics · 2025

Single- versus multi-model in the deep learning prediction of monitor units per control point for automated treatment planning in prostate cancer.

Gaudreault Mathieu, McIntosh Lachlan, Woodford Katrina, Li Jason, Harden Susan, Porceddu Sandro, Panettieri Vanessa, Hardcastle Nicholas

СтатьяПеревод в очереди

Аннотация

BACKGROUND

In contemporary radiation therapy, the radiation is modulated to conform the prescription dose to the tumor and spare organs at risk. The modulation results from a complex mathematical calculation that requires several iterations to reach a satisfactory solution, delaying treatment. The monitor units (MU) per control point (CP) control the dose magnitude and may be predicted by deep learning, a type of artificial intelligence (AI).

PURPOSE: To introduce deep learning methods to predict the MU per CP in the context of AI volumetric modulated arc therapy (VMAT) treatment plan prediction for prostate cancer.

METHODS

Patients treated for prostate cancer with 60 Gy in 20 fractions between 01/2019 and 06/2024 were considered for inclusion. Two approaches were considered: a single-model approach, trained on all samples, and a multi-model approach, with separate models trained by CP. The inputs were either the three-dimensional (3D) dose per CP (3D single-model / 3D multi-model) or the two-dimensional (2D) average dose intensity projection per CP (2D single-model / 2D multi-model). The outputs were the MU per CP, which were converted to meterset weight per CP and MU per beam to create an AI-Radiation Therapy Plan (AI-RTPlan) with other clinical parameters retained. Clinical goals achieved with the calculated dose distribution from the AI-RTPlan and clinical plan were compared.

RESULTS

The cohort was split into 220/40/42 homogeneous plans in the training/validation/testing dataset. Relative to the clinical case, the errors in meterset weight per CP were mean ± SD = -0.4 ± 3.8%/-0.2 ± 4.8% in 2D/3D single-model and 0.01 ± 3.9%/-0.1 ± 5.0% in 2D/3D multi-model. The errors in MU per beam were -0.9 ± 5.5%/-1.2 ± 4.5% in 2D/3D single-model and 0.4 ± 4.8%/0.5 ± 5.2% in 2D/3D multi-model. In 2D/3D models, at least 93%/81% of patients had the same or more clinical goals achieved with AI-RTPlans.

CONCLUSIONS

Accurate prediction of MU per CP is feasible in VMAT prostate cancer treatment.

Для цитирования: Gaudreault Mathieu, McIntosh Lachlan, Woodford Katrina, Li Jason, Harden Susan, Porceddu Sandro, Panettieri Vanessa, Hardcastle Nicholas. Single- versus multi-model in the deep learning prediction of monitor units per control point for automated treatment planning in prostate cancer.. Journal of applied clinical medical physics. 2025. DOI: 10.1002/acm2.70229.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.