MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/15376516.2018.1475537

Медицинская библиотека · Toxicology mechanisms and methods · 2018

Utilizing postmortem drug concentrations in mechanistic modeling and simulation of cardiac effects: a proof of concept study with methadone.

Mikkelsen Christian Reuss, Jornil Jakob Ross, Andersen Ljubica Vukelic, Hasselstrøm Jørgen Bo, Polak Sebastian

СтатьяПеревод в очереди

Аннотация

Methadone-related poisoning has been found to be the leading and increasing cause of death among intoxication cases in several countries. Aside from respiratory depression, methadone is known to cause QT-prolongation, which may lead to sudden cardiac death. Concentrations in heart tissue should be more accurate for estimating cardiotoxic effects. The aim of this study was to investigate whether the effect of methadone on the QT-interval could be simulated and whether the concentrations in heart tissues allowed for better prediction of the Bazett corrected QT-interval (QTcB). A predictive performance study was conducted using the simulation platform Cardiac Safety Simulator to mimic five literature studies using their described study conditions. Both free and total plasma and heart concentrations were investigated using two different in silico models: the O'Hara-Rudy (ORD) model and the 10 Tusscher (TNNP) model. The results showed that the QTcB of methadone was best predicted either with total plasma using the TNNP model or with free plasma using the ORD model. The ORD model was highly sensitive to the total heart concentrations, resulting in overprediction of the QTcB. The TNNP model also overpredicted the QTcB, but to a lesser degree than the ORD model. Furthermore, due to a low baseline QTcB, the ORD model underpredicted the QTcB for both the free plasma and free heart concentrations. In conclusion, it is possible to simulate the cardiac effects of methadone, yet several elements influence the approach uncertainty including but not limited to biophysically details model of cardiac electrophysiology, exposure data, and input parameters.

Для цитирования: Mikkelsen Christian Reuss, Jornil Jakob Ross, Andersen Ljubica Vukelic, Hasselstrøm Jørgen Bo, Polak Sebastian. Utilizing postmortem drug concentrations in mechanistic modeling and simulation of cardiac effects: a proof of concept study with methadone.. Toxicology mechanisms and methods. 2018. DOI: 10.1080/15376516.2018.1475537.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.