MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acssensors.4c00426

Медицинская библиотека · ACS sensors · 2024

Triple-Responsive, Multimodal, Visual Electronic Skin toward All-in-One Health Management for Gestational Diabetes Mellitus.

Wu Yue, Liu Yong, Yang Xueting, Tong Mingqiong, Jiang Xubao, Gu Xiangling

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Gestational diabetes mellitus (GDM) is one of the most common metabolic disorders during pregnancy, leading to serious complications for pregnant women and a threat to life safety of infants. Therefore, it is particularly important to establish a multipurpose monitoring pathway to important physiological indicators of pregnant women. In this work, three kinds of double network hydrogels are prepared with poly(vinyl alcohol) (PVA), borax, and cellulose ethers with varying substituents of methyl (methyl cellulose, MC), hydroxypropyl (hydroxypropyl cellulose, HPC), or both (hydroxypropyl methyl cellulose, HPMC), respectively. The corresponding toughness (143.9, 102.3, and 135.9 kJ cm-3) and conductivity (0.69, 0.45, and 0.51 S m-1) of the hydrogels demonstrate that PB-MC was endowed with the prominent performance. Molecular dynamics simulations further revealed the essence that hydrogen bond interactions between PVA and cellulose ethers play a critical role in regulating the structure and properties of hydrogels. Thermochromic capsule powders (TCPs) were subsequently doped in to achieve a composite hydrogel (TCPs@PB-MC) to indicate the change in human body temperature. Furthermore, the process of the TCPs@PB-MC response to glucose, pH, and temperature was tracked in-depth through the electrochemical window. This work provides a novel strategy for all-in-one health management of GDM.

Для цитирования: Wu Yue, Liu Yong, Yang Xueting, Tong Mingqiong, Jiang Xubao, Gu Xiangling. Triple-Responsive, Multimodal, Visual Electronic Skin toward All-in-One Health Management for Gestational Diabetes Mellitus.. ACS sensors. 2024. DOI: 10.1021/acssensors.4c00426.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.