Endobronchial ultrasound-guided injection of NBTXR3 radio-enhancing nanoparticles into mediastinal and hilar lymph nodes: a swine model to evaluate feasibility, injection technique, safety, nanoparticle retention and dispersion.

Casal Roberto F, Schwalk Audra J, Fowlkes Natalie, Aburto Rebeca Romero, Norton William, Dixon Katherine A, Lin Steven, Shaitelman Simona F, Chintalapani Gouthami, Hill Lori

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Loco-regionally advanced lung cancer is typically treated with a combination of chemotherapy and radiation therapy, but overall survival and local control remain poor. Radio-enhancing nanoparticles such as NBTXR3 activated by radiotherapy results in increased cell death and potentially an anti-tumor immune response. The goal of this study was to assess the feasibility and safety of endobronchial ultrasound (EBUS)-guided injection of NBTXR3 into mediastinal and hilar lymph nodes (LN), as well as assess nanoparticle retention in the LN post-injection.

METHODS

Animals underwent bronchoscopy under general anesthesia with EBUS-guided injection of NBTXR3 into hilar and mediastinal LN. LN and injection volumes were calculated based on pre-injection computed tomography (CT) scans. CT scans were repeated at 5 min, 30 min, and 8 days post-injection. Blood-draws were also obtained at baseline and post-injection. Animals were then housed, monitored, and sacrificed 8 days post-injection. Necropsy was then performed with gross and histologic analysis of LN.

RESULTS

A total of 20 LN were injected in 5 pigs (4 LN per animal). Nanoparticles were retained in 100% of LN at 30 min, and 90% of LN at 8 days. Extravasation of nanoparticles was seen in 4 out of the 20 LN. There were no cases of nanoparticle embolization visible by CT in distant organs. Small air-bubbles were introduced in the targets and surrounding tissue in 3 out of 20 LN. Of note, at 8 days, none of these air-bubbles were present on CT scan. There were no intra-procedural or post-procedural complications in either CT scans or necropsy findings. Pigs remained clinically stable and neither laboratory values nor necropsy showed evidence of inflammation.

CONCLUSIONS

EBUS-guided injection of NBTXR3 radio-enhancing nanoparticles can be safely performed achieving a high rate of nanoparticle retention, low extravasation, and no visible nanoparticle embolization.

Для цитирования: Casal Roberto F, Schwalk Audra J, Fowlkes Natalie, Aburto Rebeca Romero, Norton William, Dixon Katherine A, Lin Steven, Shaitelman Simona F, Chintalapani Gouthami, Hill Lori. Endobronchial ultrasound-guided injection of NBTXR3 radio-enhancing nanoparticles into mediastinal and hilar lymph nodes: a swine model to evaluate feasibility, injection technique, safety, nanoparticle retention and dispersion.. Journal of thoracic disease. 2020. DOI: 10.21037/jtd.2020.03.100.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.