BACKGROUND

Clinical classification methods for periocular wrinkles based on participating muscle behavior are lacking, and traditional treatment lacks detailed and individualized methods.

AIMS: This study aimed to propose a modified classification system and individualized treatment for periocular wrinkles based on the participating muscles.

PATIENTS/

METHODS

Periocular wrinkles were classified into types I.I, I.II, I.III, II, and III. A personalized treatment pattern with a multipoint, low-dose technique was developed based on wrinkle classification and severity. Standard photographs were taken and assessments made at follow-up to evaluate wrinkle severity.

RESULTS

Wrinkle severity was reduced at 1 and 3 months after periorbital botulinum toxin injection, and no serious adverse events were recorded.

CONCLUSIONS

Periorbital wrinkles were classified according to participating muscles. The modified injection pattern was individualized, effective, and safe for the treatment of periorbital wrinkles.

Для цитирования: Li Yilin, Cai Lei, Zhang Xinyu, Yin Bo, Gong Xi, Li Facheng, Han Xuefeng. Types of periocular wrinkles based on anatomical and contractile characteristics of participating periocular muscles: A modified classification method and personalized injection technique.. Journal of cosmetic dermatology. 2022. DOI: 10.1111/jocd.15197.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.