DOI 10.1016/s0379-0738(01)00586-2
Application of quantitative ethanol detector (QED) test kit to measure ethanol concentration in blood samples.
Аннотация
In this paper, the applicability of the quantitative ethanol detector (QED) test kit for screening of ethanol concentrations in blood samples was investigated. The pretreatment of blood using the sulfosalicylic acid solution and the three-way stopcock followed by membrane filtration gave satisfactory results. The ethanol concentrations in whole blood samples (n=61) determined by QED correlated well with those determined by gas chromatography; the correlation coefficient indicated 0.990. Because a high correlation coefficient (0.928) was also confirmed in trial by investigators, QED test should be highly considered for ethanol screening in forensic praxis.