MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpba.2017.11.041

Медицинская библиотека · Journal of pharmaceutical and biomedical analysis · 2018

Analysis of unbound plasma concentration of oxcarbazepine and the 10-hydroxycarbazepine enantiomers by liquid chromatography with tandem mass spectrometry in healthy volunteers.

Antunes Natalícia de Jesus, Wichert-Ana Lauro, Coelho Eduardo Barbosa, Della Pasqua Oscar, Alexandre Junior Veriano, Takayanagui Osvaldo Massaiti, Marques Maria Paula, Lanchote Vera Lucia

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

This study describes the development and validation of a method for the analysis of unbound plasma concentrations of oxcarbazepine (OXC) and of the enantiomers of its active metabolite 10-hydroxycarbazepine (MHD) [S-(+)- and R-(-)-MHD] using liquid chromatography with tandem mass spectrometry (LC-MS/MS). Additionally, the free fraction of the drug is described in healthy volunteers (n=12) after the oral administration of 300mg OXC/12h for 5days. Plasma aliquots of 200μL were submitted to ultrafiltration procedure and 50μL of the ultrafiltrate were extracted with a mixture of tert-butyl methyl ether:dichloromethane (2:1, v/v). OXC and the MHD enantiomers were separated on a OD-H chiral phase column. The method was linear in the range of 4.0-2.0μg/mL for OXC and of 20.0-6.0μg/mL plasma for the MHD enantiomers. The limit of quantification was 4ng for OXC and 20ng for each MHD enantiomer/mL plasma. The intra- and inter-day precision and inaccuracy were less than 15%. The free fraction at the time of peak plasma concentration of OXC was 0.27 for OXC, 0.37 for S-(+)-MHD and 0.42 for R-(-)-MHD. Enantioselectivity in the free fraction of MHD was observed, with a higher proportion of R-(-)-MHD compared to S-(+)-MHD.

Для цитирования: Antunes Natalícia de Jesus, Wichert-Ana Lauro, Coelho Eduardo Barbosa, Della Pasqua Oscar, Alexandre Junior Veriano, Takayanagui Osvaldo Massaiti, Marques Maria Paula, Lanchote Vera Lucia. Analysis of unbound plasma concentration of oxcarbazepine and the 10-hydroxycarbazepine enantiomers by liquid chromatography with tandem mass spectrometry in healthy volunteers.. Journal of pharmaceutical and biomedical analysis. 2018. DOI: 10.1016/j.jpba.2017.11.041.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.