m+Medelevator.RU
← Поиск публикаций
Nuclear medicine and biology · 2009

Influence of colloid particle profile on sentinel lymph node uptake.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Núñez Eutimio Gustavo Fernández, Faintuch Bluma Linkowski, Teodoro Rodrigo, Wiecek Danielle Pereira, Martinelli Jose Roberto, da Silva Natanael Gomes, Castanheira Claudia E, Filho Renato Santos de Oliveira, Pasqualini Roberto

Аннотация

INTRODUCTION: Particle size of colloids employed for sentinel lymph node (LN) detection is not well studied. This investigation aimed to correlate particle size and distribution of different products with LN uptake.

METHODS: All agents (colloidal tin, dextran, phytate and colloidal rhenium sulfide) were labeled with (99m)Tc according to manufacturer's instructions. Sizing of particles was carried out on electron micrographs using Image Tool for Windows (Version 2.0). Biodistribution studies in main excretion organs as well as in popliteal LN were performed in male Wistar rats [30 and 90 min post injection (p.i.)]. The injected dose was 0.1 ml (37 MBq) in the footpad of the left posterior limb. Dynamic images (0-15 min p.i.) as well as static ones (30 and 90 min) were acquired in gamma camera.

RESULTS: Popliteal LN was clearly reached by all products. Nevertheless, particle size remarkably influenced node uptake. Colloidal rhenium sulfide, with the smallest diameter (5.1 x 10(-3)+/-3.9 x 10(-3) microm), permitted the best result [2.72+/-0.64 percent injected dose (%ID) at 90 min]. Phytate displayed small particles (<15 microm) with favorable uptake (1.02+/-0.14%ID). Dextran (21.4+/-12.8 microm) and colloidal tin (39.0+/-8.3 microm) were less effective (0.55+/-0.14 and 0.06+/-0.03%ID respectively). Particle distribution also tended to influence results. When asymmetric, it was associated with biphasic uptake which increased over time; conversely, symmetric distribution (colloidal tin) was consistent with a constant pattern.

CONCLUSION: The results are suggesting that particle size and symmetry may interfere with LN radiopharmaceutical uptake.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты