BACKGROUND AND

OBJECTIVE

Analgesia in Ambulatory Surgery (AS) needs to evolve in parallel with surgical complexity. We designed a study to try to improve analgesia in painful surgery using an intravenous elastomeric pump. As a novelty, methadone was included.

PATIENTS AND

METHODS

An observational study, physical status ASA I-II, underwent ambulatory surgeries with moderate-severe postoperative pain. Analgesia was administered for 48h by an intravenous multimodal elastomeric pump (methadone, tramadol, dexketoprofen and ondansetron at low doses). Visual Analogue Scale (VAS) at rest and movement were evaluated at 24 and 48h. Andersen Scale, Lattinen Test, rescue analgesia and side-effects were recorded at 24h after surgery.

RESULTS

We included 73 patients: 37% abdominal wall surgery, 30% hemorrhoidectomies and 33% perineal surgery. Median VAS score at rest and movement were 0 and 3 at 24h, and 0 and 2 at 48h. At 24h, Andersen's Scale score was ≤1 in 89%, and Lattinen Test ≤6 in 90% of patients. Rescue medication was administered in 30% of patients. Two patients had vomiting at 24 and 48h. Minor catheter and pump dysfunctions were observed in 8% of patients.

CONCLUSIONS

Multimodal analgesia with intravenous methadone administered by elastomeric perfusion at home is effective and safe. However, monitoring is needed to diagnosis dysfunction of devices.

Для цитирования: Gómez-López L, Sala-Blanch X, Gambús Cerrillo P L, López Gutiérrez A, Agustí Lasús M, Anglada Casas M T. Outpatient intravenous multimodal elastomeric pump with methadone in ambulatory surgery.. Revista espanola de anestesiologia y reanimacion. 2018. DOI: 10.1016/j.redar.2018.01.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.