MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.echo.2011.03.020

Медицинская библиотека · Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 2011

Novel area strain based on three-dimensional wall motion analysis for assessment of global left ventricular performance after repair of tetralogy of Fallot.

Li Shu-na, Wong Sophia J, Cheung Yiu-fai

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

This study aimed to determine the usefulness of novel parameters of left ventricular (LV) endocardial area strain (AS) in assessing global LV performance in patients with repaired tetralogy of Fallot (TOF).

METHODS

Thirty patients, aged 21.7 ± 5.8 years, with repaired TOF and 25 healthy subjects aged 19.9 ± 5.5 years were studied. Three-dimensional LV wall motion tracking was performed to determine global and regional peak AS, an AS-systolic dyssynchrony index (SDI), and LV volumes and ejection fraction. The AS-SDI was derived from the dispersion of time-to-minimum segmental endocardial areas, expressed as a percentage of RR interval, using a 16-segment model. The LV global performance plot was generated by plotting peak global AS against AS-SDI.

RESULTS

The coefficients of variations for intra- and interobserver measurement of LV global AS were 6.3% and 10.6%, respectively. Compared with controls, patients had significantly lower global AS (30.5% ± 4.5% vs. 40.9% ± 2.8%, P < .001) and greater AS-SDI (10.0% ± 2.9% vs. 4.1% ± 1.4%, P < .001). Global AS (r = 0.94, P < .001) and AS-SDI (r = -0.76, P < .001) correlated strongly with LV ejection fraction. The global performance plot identified 87% of patients (26/30) with both reduced LV global AS and LV systolic mechanical dyssynchrony.

CONCLUSION

AS measurement of LV endocardium based on three-dimensional wall motion tracking is reproducible and enables convenient assessment of global LV performance using a composite representation of parameters, including global AS and an AS-derived index of mechanical dyssynchrony.

Для цитирования: Li Shu-na, Wong Sophia J, Cheung Yiu-fai. Novel area strain based on three-dimensional wall motion analysis for assessment of global left ventricular performance after repair of tetralogy of Fallot.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2011. DOI: 10.1016/j.echo.2011.03.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.