Single Plane Illumination Microscopy for Microfluidic Device Imaging.

Gomez-Cruz Clara, Laguna Sonia, Bachiller-Pulido Ariadna, Quilez Cristina, Cañadas-Ortega Marina, Albert-Smet Ignacio, Ripoll Jorge, Muñoz-Barrutia Arrate

СтатьяПеревод в очереди

Аннотация

Three-dimensional imaging of live processes at a cellular level is a challenging task. It requires high-speed acquisition capabilities, low phototoxicity, and low mechanical disturbances. Three-dimensional imaging in microfluidic devices poses additional challenges as a deep penetration of the light source is required, along with a stationary setting, so the flows are not perturbed. Different types of fluorescence microscopy techniques have been used to address these limitations; particularly, confocal microscopy and light sheet fluorescence microscopy (LSFM). This manuscript proposes a novel architecture of a type of LSFM, single-plane illumination microscopy (SPIM). This custom-made microscope includes two mirror galvanometers to scan the sample vertically and reduce shadowing artifacts while avoiding unnecessary movement. In addition, two electro-tunable lenses fine-tune the focus position and reduce the scattering caused by the microfluidic devices. The microscope has been fully set up and characterized, achieving a resolution of 1.50 μm in the x-y plane and 7.93 μm in the z-direction. The proposed architecture has risen to the challenges posed when imaging microfluidic devices and live processes, as it can successfully acquire 3D volumetric images together with time-lapse recordings, and it is thus a suitable microscopic technique for live tracking miniaturized tissue and disease models.

Для цитирования: Gomez-Cruz Clara, Laguna Sonia, Bachiller-Pulido Ariadna, Quilez Cristina, Cañadas-Ortega Marina, Albert-Smet Ignacio, Ripoll Jorge, Muñoz-Barrutia Arrate. Single Plane Illumination Microscopy for Microfluidic Device Imaging.. Biosensors. 2022. DOI: 10.3390/bios12121110.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.